Preliminary
8.4 BASE REFERENCE POINT ADJUSTMENT (Cont'd)
8.4.3 Limitation on Base Reference Point Adjustment
After adjustment of the print position and the stop position for options, the distance between these two
positions should not exceed one pitch size (including liner) of the media.
Refer to the figure and table below for the adjustment range of the distance between the print position and the
stop position for options.
Adjustment range of the distance between the print position and the stop position for options:
Types of Options
Tear-off
Cutter
Dispenser
CW408 Operator Manual
Stop position
for options
(Initial)
Initial distance
Adjusted distance
(Min.)
+3.75 mm
-3.75 mm
+3.75 mm
(+0.15")
(-0.15")
Adjusted distance (Max.)
Adjusted Distance
(Min.)
12.5 mm (0.49")
16.5 mm (0.65")
5.5 mm (0.22")
Print position
(Initial)
The range of the adjusted distance includes
the base reference point of two media.
-3.75 mm
(+0.15")
(-0.15")
Initial Distance
20.0 mm (0.78")
24.0 mm (0.94")
13.0 mm (0.51")
Section 8: Appendix
Adjusted Distance
(Max.)
27.5 mm (1.08")
31.5 mm (1.24")
20.5 mm (0.81")
Page 8-7