Note: Make sure that Configure Bins is not set to Link.
1
From the Diagnostics menu, select OUTPUT BIN TESTS > Feed Tests.
2
Select an output bin to test.
Note: Only the installed bins are listed in the menu.
3
Select one of the following:
•
Single—This feeds a single page.
•
Continuous—This continuously feeds pages until the Stop button is pressed.
4
Touch Back to return to OUTPUT BIN TESTS.
Sensor Test (standard bin)
This test verifies whether the standard bin sensor is working correctly.
1
From the Diagnostics menu, navigate to:
OUTPUT BIN TESTS > Sensor Test > Standard Bin
Note: The current state of the sensor appears on the control panel display.
Manually actuate the sensor to make it toggle between Open and Closed or between empty and full,
2
depending on the printer model. If the sensor does not toggle, then the sensor is malfunctioning.
3
Press the Stop button to exit the test.
BASE SENSOR TEST
This test determines whether the following sensors inside the printer are working properly.
•
Toner level sensor
•
Narrow media sensor
•
Input sensor
•
Output (exit) sensor
•
Front door sensor
CAUTION—SHOCK HAZARD: Do not use your hand to toggle these switches. Use a nonconducting
item.
1
From the Diagnostics menu, select BASE SENSOR TEST.
2
Select a sensor.
Manually actuate the sensor to make it toggle between Open and Closed. If the sensor does not toggle,
3
then it is malfunctioning.
Note: Remove and then reinstall the toner cartridge to actuate the toner level sensor.
4
Press the Stop button to exit the test.
Service menus
271