3
Remove the three screws (A) securing the HCIT controller card assembly.
A
4
Remove the HCIT controller card assembly and the shield.

High capacity input tray (HCIT) media size actuator assembly removal

Note: Carefully remove the base machine from the HCIT tray assembly before proceeding.
1
Remove the HCIT controller card assembly. Go to
removal" on page
428.
2
Disconnect the two springs (A) from the frame.
Note: Leave the springs (A) attached to the cam size sensing plate (B) and the actuator switch (C).
"High capacity input tray (HCIT) controller card assembly