Sensor (mailbox empty) static jam service check
Action
Step 1
Check and clear the media path for partially fed or jammed media.
Does the problem remain?
Step 2
Check the sensor (mailbox empty) for proper operation.
a
Enter the Diagnostics menu, and then navigate to:
Output bin tests > Sensor test > Output bin [x]
b
Observe the line item, "mailbox empty."
Does the display on the operator panel change every time the
sensing area of the sensor is interrupted or blocked?
Step 3
a
Check the sensor (mailbox empty) for proper connection.
b
Replace the connection, if necessary.
Does the problem remain?
Step 4
Replace the sensor (mailbox empty). Go to
assembly sensor (mailbox empty) removal" on page
Does the problem remain?
Step 5
Perform a print test using the option.
Does the problem remain?
Step 6
Replace the output option.
Does the problem remain?
"4-bin mailbox
398.
Diagnostic information
146
Yes
No
Go to step 2.
The problem is
solved.
Go to step 5.
Go to step 3.
Go to step 4.
The problem is
solved.
Go to step 5.
The problem is
solved.
Go to step 6.
The problem is
solved.
Contact the next
The problem is
level of support.
solved.