Checklist D Procedures
8
Fully retract the boom and raise the boom to
full height. Visually inspect the the dial
indicator to be sure the needle returns to the
"zero" position.
9
Remove the dial indicator and rotate the
turntable 90°.
10 Repeat steps 4 through 9 until the rotation
bearing has been checked in at least four
equally spaced areas 90° apart.
11 Lower the boom to the stowed position and
turn the machine off.
12 Remove the dial indicator from the machine.
62
D-5

Replace the Hydraulic Filters

Genie specifications require that this procedure be
performed every 1000 hours or annually,
whichever comes first.
Perform this procedure more often if dusty
conditions exist.
Replacement of the hydraulic filters is essential for
good machine performance and service life. A dirty
or clogged filter may cause the machine to perform
poorly and continued use may cause component
damage. Extremely dirty conditions may require
that the filter be replaced more often.
Note: Perform this procedure with the engine off.
Hydraulic return filter
1
Open the ground controls side turntable cover
and locate the hydraulic return filter housing
on top of the hydraulic tank.
2
Remove the cap from the filter housing.
3
Lift the handle on the filter element and rotate
the element counterclockwise to release the
element from the housing.
4
Remove the filter element from the housing.
5
Install the new filter element into the filter
housing.
6
Push the filter element down to be sure the
O-ring on the element is fully seated into the
housing.
S-80 • S-85 • S-80X
February 2017
Bodily injury hazard. Beware of
hot oil. Contact with hot oil may
cause severe burns.
Part No. 1259369GT