Checklist B Procedures
B-3

Check the Exhaust System

Genie specifications require that this procedure be
performed every 250 hours or quarterly, whichever
comes first.
Maintaining the exhaust system is essential to
good engine performance and service life.
Operating the engine with a damaged or leaking
exhaust system can cause component damage
and unsafe operating conditions.
Bodily injury hazard. Do not
inspect while the engine is
running. Remove the key to
secure from operation.
Burn hazard. Beware of hot
engine components. Contact
with hot engine components
may result in severe burns.
To access the engine:
1
Remove the engine tray retaining fastener
located under the engine tray. Swing the
engine tray out away from the machine and
secure it from moving.
Crushing hazard. Failure to
install the fastener into the
engine tray anchor hole to secure
the engine tray from moving
could result in death or serious
injury.
2
Be sure that all nuts and bolts are tight.
3
Inspect all welds for cracks.
4
Inspect for exhaust leaks; i.e., carbon buildup
around seams and joints.
32
5
Swing the engine pivot plate in towards the
machine.
6
Install the bolts that were just removed into the
original holes to secure the engine pivot plate.
S-80 • S-85 • S-80X
February 2017
Crushing hazard. Failure to
install the bolts into the engine
pivot plate to secure it from
moving could result in death or
serious injury.