Service Manual
Checklist C Procedures
6
Move the primary boom down joystick off
center and retract the primary boom until the
unrestricted platform capacity light stops
flashing.
Result: Primary boom down should return to
normal operation.
7
Lower the primary boom 5 feet / 1.5 m and
activate primary boom extend.
Result: Primary boom extend will stop and the
unrestricted platform capacity light will start
flashing.
8
Activate primary boom extend and raise the
primary boom until the unrestricted platform
capacity light stops flashing.
Result: Primary boom extend should return to
normal operation.
9
Return the machine to the fully stowed
position.
56
S-80 • S-85 • S-80X
February 2017
Part No. 1259369GT