Checklist E Procedures

E-1

Test or Replace the Hydraulic Oil

Genie specifications require that this procedure be
performed every 2000 hours or every two years,
whichever comes first.
Perform this procedure more often if dusty
conditions exist.
Replacement or testing of the hydraulic oil is
essential for good machine performance and
service life. Dirty oil and a clogged suction strainer
or hydraulic filters may cause the machine to
perform poorly and continued use may cause
component damage. Extremely dirty conditions
may require oil changes to be performed more
frequently.
Note: Before replacing the hydraulic oil, the oil may
be tested by an oil distributor for specific levels of
contamination to verify that changing the oil is
necessary. If the hydraulic oil is not replaced at the
two year inspection, test the oil quarterly. Replace
the oil when it fails the test.
Note: When removing a hose assembly or fitting,
the O-ring (if equipped) on the fitting and/or hose
end must be replaced. All connections must be
torqued to specification during installation. Refer to
Specifications, Hydraulic Hose and Fitting Torque
Specifications.
Note: Perform this procedure with the boom in the
stowed position.
1
Remove the fuel tank. Refer to Repair
Procedure, How to Remove the Fuel Tank.
68
2
Models without hydraulic tank shutoff
valves: Remove the drain plug from the
hydraulic tank and completely drain the tank
into a suitable container. Refer to
Specifications, Machine Specifications.
Models with hydraulic tank shutoff valves:
Close the two hydraulic tank valves located at
the hydraulic tank.
open
3
Remove the drain plug from the hydraulic tank
and completely drain the tank into a container
of suitable capacity. Refer to Specifications,
Machine Specifications.
4
Tag, disconnect and plug the two suction
hoses that are attached to the hydraulic tank
shutoff valves.
5
Disconnect and plug the T-fitting located at the
return filter with the two hoses connected to it.
Cap the fitting on the return filter housing.
S-80 • S-85 • S-80X
February 2017
closed
Component damage hazard.
The engine must not be started
with the hydraulic tank shut-off
valves in the closed position or
component damage will occur. If
the tank valves are closed,
remove the key from the key
switch and tag the machine to
inform personnel of the
condition.
Part No. 1259369GT