Genie S-80 Service Manual page 196

Hide thumbs Also See for S-80:
Table of Contents

Advertisement

Service Manual
Continental TME27 Engine Fault Codes
System
Code Fault Name
Cam Crank
342
Cam Loss
Sensors
337
Crank Loss
341
Cam Sync Noise
336
Crank Sync Noise
16
Never Crank Synced at
Start
Internal
606
COP Failure
Process or
1612
RTI 1 Loss
Diagnostics
1613
RTI 2 Loss
1614
RTI 3 Loss
1615
A/D Loss
1616
Invalid Interrupt
601
Flash Checksum Invalid
604
RAM Failure
J1939
1625
Shutdown Request
Network
1626
CAN Tx Failure
1627
CAN Rx Failure
1628
CAN Address Conflict
Failure
1 = Shutdown
2 = AL disable
176
1 2 3 4 5
Y Y
Y Y
Y Y
Y
Y
Y
Y
Y
Y
Y
Y
3 = AL disable key-cycle
S-80 • S-85 • S-80X
6
Fault Conditions
No cam pulse in 4 cycles and RPM > 1000
Cam pulses without crank activity > 6 cam
pulses
Number of invalid cam re-syncs = 1 within a
time window of <= 700 ms
Number of invalid crank re-syncs = 1 within a
time window of <= 800 ms
Cranking revs without sync < 4 revs and RPM >
90 rpm
Y
Y
Y
Y
Y
Y
Y
Y
Number of shutdown requests >= 1
TX error counter > 100
Rx error counter > 100
Address conflict counter > 5
4 = Power derate 1
5 = Power derate 2
February 2017
6 = Low rev limit
Part No. 1259369GT

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-85S-80x

Table of Contents