5. PARAMETERS

5. PARAMETERS
CAUTION

5.1 Parameter list

5.1.1 Parameter write inhibit

In the MR-J2S-A servo amplifier, its parameters are classified into the basic parameters (No. 0 to 19),
expansion parameters 1 (No. 20 to 49) and expansion parameters 2 (No.50 to 84) according to their safety
aspects and frequencies of use. In the factory setting condition, the customer can change the basic
parameter values but cannot change the expansion parameter values. When fine adjustment, e.g. gain
adjustment, is required, change the parameter No. 19 setting to make the expansion parameters write-
enabled.
The following table indicates the parameters which are enabled for reference and write by the setting of
parameter No. 19. Operation can be performed for the parameters marked
Parameter No. 19 setting
0000
(initial value)
000A
000B
000C
000E
100B
100C
100E
Never adjust or change the parameter values extremely as it will make operation
instable.
POINT
After setting the parameter No. 19 value, switch power off, then on to
make that setting valid.
Basic parameters
Operation
No. 0 to No. 19
Reference
Write
Reference
No. 19 only
Write
No. 19 only
Reference
Write
Reference
Write
Reference
Write
Reference
Write
No. 19 only
Reference
Write
No. 19 only
Reference
Write
No. 19 only