10. TROUBLESHOOTING
Display
Name
AL.E5 ABS time-out
warning
AL.E6 Servo emergency
EMG is off.
stop warning
AL.E9 Main circuit off
Servo-on (SON) was
warning
switched on with main
circuit power off.
AL.EA ABS
Servo-on (SON) turned on
servo-on warning
more than 1s after servo
amplifier had entered
absolute position data
transfer mode.
Definition
1. PLC ladder program wrong.
2. Reverse rotation start (ST2) Limiting
torque (TLC) improper wiring
External emergency stop was made valid.
(EMG was turned off.)
1. PLC ladder program wrong.
2. Servo-on (SON) improper wiring.
10 - 14
WWW.NNC.IR
Cause
Contact the program.
Connect properly.
Ensure safety and deactivate
emergency stop.
Switch on main circuit power.
1. Correct the program.
2. Connect properly.
Action