Mitsubishi Electric MR-J2S-A Instruction Manual page 137

Servo amplifier
Hide thumbs Also See for MR-J2S-A:
Table of Contents

Advertisement

5. PARAMETERS
Class No. Symbol
21
*OP3
Function selection 3 (Command pulse selection)
Used to select the input form of the pulse train input signal.
(Refer to section 3.4.1)
22
*OP4
Function selection 4
Used to select stop processing at forward rotation stroke end (LSP)
reverse rotation stroke end (LSN) off and choose VC/VLA voltage
averaging.
0
Name and function
0 0
Command pulse train input form
0: Forward/reverse rotation pulse train
1: Signed pulse train
2: A B-phase pulse train
Pulse train logic selection
0: Positive logic
1: Negative logic
0
How to make a stop when forward
rotation stroke end (LSP)
(LSN) is valid. (Refer to section 5.2.3)
0: Sudden stop
1: Slow stop
VC/VLA voltage averaging
Used to set the filtering time when the analog speed
command (VC) voltage or analog speed limit (VLA) is
imported.
Set 0 to vary the speed to voltage fluctuation in real
time. Increase the set value to vary the speed slower
to voltage fluctuation.
Set
Filtering time [ms]
value
0
0
1
0.444
2
0.888
3
1.777
4
3.555
5 - 14
WWW.NNC.IR
Initial
value
0000
0000
reverse rotation stroke end
Setting
Control
Unit
range
mode
P
Refer to
Name
and
function
column.
Refer to
Name
and
function
column.
P S
P S T

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents