Mitsubishi Electric MR-J2S-A Instruction Manual page 93

Servo amplifier
Hide thumbs Also See for MR-J2S-A:
Table of Contents

Advertisement

3. SIGNALS AND WIRING
(7) Source input interface
When using the input interface of source type, all Dl-1 input signals are of source type. Source output
cannot be provided.
For use of internal power supply
(Note)
For a transistor
Approx. 5mA
Switch
TR
V
1.0V
CES
I
100 A
CEO
Note. This also applies to the use of the external power supply.
When using the input interface of source type, all Dl-1 input signals are of source type. Source output
cannot be provided.
For 11kW or more, the source input interface cannot be used with the internal power supply. Always
use the external power supply.
MITSUBISHI
Note. The jumper, which is shown black for the convenience of explanation, is actually white.
Servo amplifier
SG
R: Approx. 4.7
COM
SON,
etc.
24VDC
VDD
CON2
JP11
3 - 46
WWW.NNC.IR
For use of external power supply
Servo amplifier
SG
COM
Switch
SON,etc.
24VDC
200mA or more
CON2
JP11
(Note)
Jumper
For sink input (factory setting)
R: Approx. 4.7
CON2
JP11
(Note)
Jumper
For source input

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents