5. PARAMETERS
Class No. Symbol
65
*CDP
Gain changing selection
Used to select the gain changing condition. (Refer to section 8.3)
0 0
66
CDS
Gain changing condition
Used to set the value of gain changing condition (command
frequency, droop pulses, servo motor speed) selected in parameter
No. 65.The set value unit changes with the changing condition item.
(Refer to section 8.5)
67
CDT
Gain changing time constant
Used to set the time constant at which the gains will change in
response to the conditions set in parameters No. 65 and 66.
(Refer to section 8.5)
68
For manufacturer setting
Do not change this value by any means.
69
CMX2 Command pulse multiplying factor numerator 2
Used to set the multiplier for the command pulse.
Setting "0" automatically sets the connected motor resolution.
70
CMX3 Command pulse multiplying factor numerator 3
Used to set the multiplier for the command pulse.
Setting "0" automatically sets the connected motor resolution.
71
CMX4 Command pulse multiplying factor numerator 4
Used to set the multiplier for the command pulse.
Setting "0" automatically sets the connected motor resolution.
72
SC4
Internal speed command 4
Used to set speed 4 of internal speed commands.
Internal speed limit 4
Used to set speed 4 of internal speed limits.
Name and function
0
Gain changing selection
Gains are changed in accordance with the settings
of parameters No. 61 to 64 under any of the following
conditions:
0: Invalid
1: Gain changing (CDP) signal is ON
2: Command frequency is equal to higher than
parameter No. 66 setting or more
3: Droop pulse value is equal to higher than
parameter No. 66 setting or more
4: Servo motor speed is equal to higher than
parameter No. 66 setting or more
5 - 24
WWW.NNC.IR
Initial
Setting
Control
Unit
value
range
mode
0000
P S
Refer to
Name
and
function
column.
10
kpps
10
P S
pulse
to
r/min
9999
1
ms
0
P S
to
100
0
1
0 1
P
to
65535
1
0 1
P
to
65535
1
0 1
P
to
65535
200
r/min 0 to in-
S
stanta-
neous
T
permi-
ssible
speed