5. PARAMETERS
Class No. Symbol
73
SC5
Internal speed command 5
Used to set speed 5 of internal speed commands.
Internal speed limit 5
Used to set speed 5 of internal speed limits.
74
SC6
Internal speed command 6
Used to set speed 6 of internal speed commands.
Internal speed limit 6
Used to set speed 6 of internal speed limits.
75
SC7
Internal speed command 7
Used to set speed 7 of internal speed commands.
Internal speed limit 7
Used to set speed 7 of internal speed limits.
76
TL2
Internal torque limit 2
Set this parameter to limit servo motor torque on the assumption
that the maximum torque is 100[%].
When 0 is set, torque is not produced. (Refer to section 3.4.1 (5))
77
For manufacturer setting
Do not change this value by any means.
78
79
80
81
82
83
84
Name and function
5 - 25
WWW.NNC.IR
Initial
Setting
Control
Unit
value
range
mode
r/min 0 to in-
300
S
stanta-
neous
permi-
T
ssible
speed
r/min 0 to in-
500
S
stanta-
neous
permi-
T
ssible
speed
r/min 0 to in-
800
S
stanta-
neous
permi-
T
ssible
speed
100
%
0
P S T
to
100
00
10000
10
10
100
100
100
0000