13. OPTIONS AND AUXILIARY EQUIPMENT
b. Losses of servo motor and servo amplifier in regenerative mode
The following table lists the efficiencies and other data of the servo motor and servo amplifier in
the regenerative mode.
Servo amplifier
MR-J2S-10A
MR-J2S-10A1
MR-J2S-20A
MR-J2S-20A1
MR-J2S-40A
MR-J2S-40A1
MR-J2S-60A
MR-J2S-70A
MR-J2S-100A
MR-J2S-200A
MR-J2S-350A
MR-J2S-500A
MR-J2S-700A
MR-J2S-11KA
MR-J2S-15KA
MR-J2S-22KA
Inverse efficiency ( )
Capacitor charging (Ec)
Subtract the capacitor charging from the result of multiplying the sum total of regenerative energies
by the inverse efficiency to calculate the energy consumed by the regenerative option.
Calculate the power consumption of the regenerative option on the basis of single-cycle operation
period tf [s] to select the necessary regenerative option.
(3) Connection of the regenerative option
Set parameter No.2 according to the option to be used.
The MR-RB65, 66 and 67 are regenerative options that have encased the GRZG400-2 , GRZG400-1
and GRZG400-0.8 , respectively. When using any of these regenerative options, make the same
parameter setting as when using the GRZG400-2 , GRZG400-1
regenerative resistors or regenerative option is used with 11kW or more servo amplifier).
Parameter No.0
Inverse efficiency[%]
Capacitor charging[J]
55
55
70
70
85
85
85
80
80
85
85
90
90
90
90
90
:Efficiency including some efficiencies of the servo motor and servo
amplifier when rated (regenerative) torque is generated at rated speed.
Since the efficiency varies with the speed and generated torque, allow for
about 10%.
:Energy charged into the electrolytic capacitor in the servo amplifier.
ER [J]
Es
Ec
PR [W]
ER/tf
Selection of regenerative
00: Regenerative option or regenerative option is not used with 7kW or
less servo amplifier
Supplied regenerative resistors or regenerative option is used with
11kW or more servo amplifier
01: FR-RC, FR-BU2, FR-CV
02: MR-RB032
03: MR-RB12
04: MR-RB32
05: MR-RB30
06: MR-RB50 (Cooling fan is required)
08: MR-RB31
09: MR-RB51 (Cooling fan is required)
0E: When regenerative resistors supplied to 11kW or more are cooled by
cooling fans to increase capability
13 - 3
WWW.NNC.IR
9
4
9
4
11
12
11
18
18
40
40
45
70
120
170
250
or GRZG400-0.8
(supplied