13. OPTIONS AND AUXILIARY EQUIPMENT
(d) MR-J2S-11KA-PX to MR-J2S-22KA-PX (when using the regenerative option)
The MR-J2S-11KA-PX to MR-J2S-22KA-PX servo amplifiers are not supplied with regenerative
resistors. When using any of these servo amplifiers, always use the MR-RB65, 66 or 67
regenerative option.
The MR-RB65, 66 and 67 are regenerative options that have encased the GRZG400-2 , GRZG400-
1
and GRZG400-0.8 , respectively. When using any of these regenerative options, make the
same parameter setting as when using the GRZG400-2 , GRZG400-1
(supplied regenerative resistors or regenerative option is used with 11kW or more servo amplifier).
Cooling the regenerative option with cooling fans improves regenerative capability.
The G3 and G4 terminals are for the thermal sensor. G3-G4 are opened when the regenerative
option overheats abnormally.
Servo amplifier
P
1
P
C
COM
ALM
Configure up a circuit which
shuts off main circuit power
when thermal sensor operates.
Note. Specifications of contact across G3-G4
Maximum voltage
Maximum current
Maximum capacity : 2.4VA
Servo Amplifier
MR-J2S-11KA-PX
MR-J2S-15KA-PX
MR-J2S-22KA-PX
When using cooling fans, install them using the mounting holes provided in the bottom of the
regenerative option. In this case, set "0E
2 cooling fans
(92 92, minimum air flow: 1.0m
Do not remove
Regenerative option
the short bar.
P
C
RA
G3
(Note)
G4
: 120V AC/DC
: 0.5A/4.8VDC
Regenerative
Resistance
Option Model
[ ]
cooling fans
MR-RB65
8
MR-RB66
5
MR-RB67
4
Top
Bottom
TE1
)
3
Mounting screw
4-M3(0.118)
13 - 7
WWW.NNC.IR
Regenerative Power [W]
Without
With
cooling fans
500
800
850
1300
850
1300
" in parameter No. 0.
MR-RB65 66 67