Sp5: Mode - Ricoh G108 Service Manual

Hide thumbs Also See for G108:
Table of Contents

Advertisement

SERVICE PROGRAM MODE

SP5: Mode

5024*
mm/inch Display
Sets the unit of measure.
5045*
Counter Method
Sets the development counter or the print counter for the meter charge
(Engine SP5-930-001). You can change the setting of Engine SP5-045 only
one time.
5302*
Set Time
Adjusts the RTC (real time clock) time setting. Sets the local time. (Montreal: -
300, Paris: + 60, Beijing: +480, Taipei: +480, Hong Kong: +480)
5404
User Code Counter Clear
Clears all user counters.
5501*
PM Alarm
Sets the PM alarm level. A PM alarm goes on at this time: PA x 1000 = PC,
where PA is the value set in Engine SP5-501 and PC is the value in the PM
counter.
5504*
Jam Alarm
Sets the jam alarm level. If a paper jam occurs, the jam alarm counter
increases by +1. If no paper jam occurs while the specified number of paper is
output, the jam alarm counter decreases by -1. The jam alarm is issued when
the jam alarm counter reaches +10.
5505*
Error Alarm
Sets the error alarm level. If an SC code is generated, the error alarm counter
increases by +1. If no SC code is generated while the specified number of
paper is output, the jam alarm counter decreases by -1. The error alarm is
issued when the error alarm counter reaches +5.
G108
[0 ∼ 1 / Europe: 0, North America: 1 / 1/step]]
[0 ∼ 1 / 1 / 1/step] 0: Developments, 1: Prints
[-1440 ∼ 1440 / - / 1 minute/step] DFU
[0 ∼ 9999 / 0 / 1/step] DFU
0: Disables the PM alarm
[0 ∼ 3 / 3 / 1/step] DFU
3: 6K, 2: 3K, 1: 1.5K, 0: Disables the jam alarm
[0 ∼ 255 / 50 / 1/step] DFU
0: Disables the PM alarm
5-12
Rev. 12/2004
SM

Advertisement

Table of Contents
loading

Table of Contents