Sp5-Xxx (Mode) - Ricoh G190 Service Manual

Hide thumbs Also See for G190:
Table of Contents

Advertisement

Service Mode Table

SP5-XXX (Mode)

5001
[All Indicators On]
5001 001
5024
[mm/ inchDisplay]
5024 001
5045
[Accounting count]
5045 001
Counter Method
5051
[Refill Toner Disp] Toner Refill Display
5051 001
Refill Toner Disp
G190
Checks the LED on the operation panel.
*CTL
0: Normal, 1: All lit
Sets units (mm or inch) for custom paper
sizes.
*CTL
[0 or 1 / 1 /-]
0: mm (EU/AS), 1: inch (NA)
Selects the counting method if the meter
charge mode is enabled with SP5-930-001.
*CTL
[0 to 2 / 1 / -]
0: Developments, 1: Pages, 2:Coverage
range
Enable or disable the warning display when
you install a toner bottle that was refilled by
*CTL
third party venders.
[0 or 1 / 0 / -]
0: Enable, 1: Disable
5-136
SM

Advertisement

Table of Contents
loading

Table of Contents