SERVICE CALL
Code
Class
490
D
Transfer roller clutch error
515
D
Duplex unit controller
hardware error 1
516
D
Duplex unit controller
hardware error 2
517
D
Duplex motor error
520
D
Main motor error
521
D
Paper gate solenoid error
530
D
Controller fan error
531
D
Optics unit fan error
532
D
Fusing fan error
540
D
Scanner motor error
541
D
Thermistor short-circuit error
542
D
Fusing lamp error
543
Fusing temperature error
during warming up
544
Fusing temperature error
during on
545
Fusing temperature error
during off
546
AC relay off error
547
D
Fusing clutch error
610
D
High voltage unit connection
error
611
D
Toner end sensor error 1
612
Toner end sensor error 2
G108
Error
• Loose connection
• Defective solenoid
• Defective input output device or BCU
• Loose connection between the BCU and
• Loose connection between the BCU and
• One of the fuses on the duplex unit
NOTE: These fuses prevent excess current
from flowing into the motors.
• Loose connection
• Safety interlock switch
• Defective motor
• Defective input output device
• Interlock Safety Switch
• Loose connection
• Defective solenoid
• Defective duplex-unit controller
• Loose connection
• Defective fan
• Defective input output device
• Defective BCU
• Loose connection
• Defective LD unit
• Defective BCU
• Loose connection
• Incorrect installation of the fusing unit
• Defective fusing unit
• Defective BCU
• Loose connection
• Defective thermistor
• Defective fusing unit
• Defective power supply unit
• Defective BCU
• Insufficient power supply
• Loose connection
• Defective clutch
• Defective input output device
• Defective BCU
• Loose connection
• Defective high voltage unit
• Defective BCU
• Loose connection of the emitter of the
• Defective PCB of the receptor of the
• Defective input output device
• Defective PCB of the emitter of the toner
• Defective BCU
4-4
Possible Cause
the duplex unit controller board
the duplex unit controller board
controller has blown.
toner end sensor
toner end sensor
end sensor
SM