SERVICE PROGRAM MODE
Bit Switches
Do not change the bit switches unless
you are instructed to do so by the
manufacturer.
1. Enter SP mode. The menu item
"1. Service" is shown.
2. Press the Enter key [D] two times.
3. To select a bit switch, press the up-
arrow key [B] or the down-arrow key
[C].
4. Press the Enter key.
5. Set the desired value:
• Press the up-arrow key [B] or the
down-arrow key [C] to move the
cursor.
• To select one of the bits, press the
Enter key.
• To change the value, press the up-arrow key or the down-arrow key.
• To keep the value, press the Enter key.
• To quit the bit switch, press the Escape key.
NOTE: The leftmost digit [E] is bit 7 and the
rightmost digit [F] is bit 0.
6. Press the Escape key several times until the menu
"1. Service" is shown.
7. Select "End" by pressing the Enter key. Use the up or down arrow keys to
locate "3. End."
G108
Online
Job Reset Escape
[A]
Form Feed
Power
5-6
Menu
#Enter
Alert
Data In
G108S901.WMF
[E]
Sw#1
00000000
bit0
_
[B]
[C]
[D]
[F]
SM