2. Select the alarm input number of a camera, which corresponds to the connector on the back
panel of the recorder, and enter the name of the input, if required.
3. Select the alarm input type, NO (normally open) or NC (normally closed). Default is NO.
4. Check the
Enable Alarm Input
5. Select the arming schedule for the external alarm.
Click the
Arming Schedule
and the time periods during the day when an external alarm can be detected. You can
schedule up to eight time periods in a day. Default is 24 hours.
If you want to copy the arming schedule to other alarm inputs, under "Copy to alarm" select
the desired alarm inputs.
Note: Time periods defined cannot overlap.
6. Specify the linkage method when an event occurs.
Under the
Actions
by which you want the recorder to notify you of the alarm: Enable Alarm Audio, Notify Alarm
Host, Send Email (see page 80 for the description of these alarm notification types).
7. In the Actions window, specify which alarm outputs are triggered when an event occurs.
8. Select the cameras to be triggered when an external alarm is detected.
In the Actions window, specify which channels are triggered when an event occurs.
9. Select the PTZ camera function required in response to an external alarm.
In the Actions window, specify the
preset, preset tour or shadow tour that is triggered when the alarm is detected.
10. If you want to copy the alarm linking, trigger alarm output, trigger channel or PTZ linking
settings to other alarm inputs select the desired alarm inputs under "Copy to alarm".
11. Click
Apply
to save the settings.

Set up alarm outputs

You can connect the recorder to an alarm system, such as a siren or intrusion system, which is
then activated when an alarm is triggered. You can select how long the alarm signal remains
active as well as schedule when alarm outputs can be triggered.
"A" outputs are marked A for analog and are physical outputs of the recorder. "D" outputs are
marked as D for digital and are physical outputs on the IP cameras.
To set up an alarm output:
1. From the menu toolbar, click
Setup
>
Alarm
Output.
2. Select the alarm output. Enter a name for it, if desired (the name cannot be copied).
3. Select a time out option between 5 and 600 seconds or select "Manually Clear".
TruVision NVR 70 User Manual
box.
tab and then click the
tab click the
Edit
button to open the Actions window. Select the method
PTZ
Linking. Select the PTZ camera and enter the
Configuration
12BChapter 13: Alarm and event setup
Edit
button. Select the day of the week
>
Remote Configuration
>
Alarm & Event
79