AIR CONDITIONING
HE:ATER CONTROL ASSEMBLY
CONNECT A/C CONTROL CABLES
3.
Set air inlet control lever to "RECIRC" position.
(a)
Set temperature control dial to "MAX. COOL" position.
(b)
(c)
Set made control dial to "DEF" position.
Adjust air inlet damper control cable.
(d)
Set air inlet damper control lever to "RECIRC" position
and connect the inner cable to lever pin and clamp the
outer cable.
HINT:
Lock the damp while lightly pushing the outer cable to the direc
tion shown by arrow in the illustration.
Adjust air mix damper control cable.
(e)
Set air mix damper control lever to "MAX. COOL" position
and connect the inner cable to lever pin and clamp the
outer cable.
HINT:
Lock the clamp while lightly pushing the outer cable to the direc
tion shown by arrow in the illustration.
Adjust air outlet damper control cable.
(f)
Pull the air ou!let damper control link to "DEF" position,
connect the control cable and lock the clamp.
HINT:
Lock the clamp while lightly pushing the outer cable to the direc
tion shown by arrow in the illustration.
AC-71