AC--4 8
·•
AIR
CONDITIONING
BLOWER MOTOH
B LOWER MOTOR
INSPECTION
1 .
REMOVE GLOVE COMPARTMENT PARTS
(See page B0-79)
2.
REMOVE BLOWER MOTOR
Remove the wire harness damp and disconnect the con
(a )
nector.
Remove the 3 screws and motor.
{b)
INSPECT BLOWER MOTOR OPERATION
3.
Connect the positive ( +) lead from the battery to terminal 1 and
the negative (-) lead to terminal 2, then check that the motor op
erations smoothly.
If operation is not as specified, replace the blower motor.
INSTALL BLOWER MOTOR
4.
Install the motor and 3 screws.
(a)
Connect the connector and wire harness clamp.
(b)
5.
INSTALL GLOVE COMPARTMENT PARTS
(See page B0-85)