Mter initial setup, issue the following commands from the keyboard of each
MicroVAX 3100 multiuser system:
1.
SET MOP command enables or disables the network listener.
SET MOP 1 enables the listener bit.
Enable the listener bit using the SET MOP command as follows:
»>
SET MOP 1
I
Return
I
»>
SET MOP 0 disables the listener bit.
2. The SET TRIG command allows a remote system to request a local boot
of the system. SET TRIG 1 enables the remote system's request.
Go to each MicroVAX 3100 multiuser system and enable the state of
the remote trigger using the SET TRIG command as follows:
»>
SET TRIG 1
I
Return
I
»>
SET TRIG 0 disables the remote systems request.
3. The password is set with the SET PSWD command. The value for the
password can be any 16 hexadecimal characters, 0 through 9 and A
through F. For security reasons, the password is one-way encrypted
and cannot be displayed. In order to set a new password, the password
must be known unless it is the first time the password is set.
»>
SET PASSWORD password
»>
To change a password, enter the SET PSWD command specifying first
the new password followed by the old password.
»>
SET PASSWORD
new~assword old~assword
»>
With the server booted, and the operating system and networking
software installed and running, enter the following commands at the
server keyboard:
$ MCR NCP
I
Return
I
NCP> TRIG NODE remote system name SERVICE
PAS SWORD-
I
Return
I
-
-
-NCP>
your~assword
I
Return
I
The remote system should boot.