Adjusting The Exhaust Gas Volume - Yamaha XP500 Service Manual

Hide thumbs Also See for XP500:
Table of Contents

Advertisement

SYNCHRONIZING THE THROTTLE BODIES/

ADJUSTING THE EXHAUST GAS VOLUME

1
2
1
2
9. Stop the engine and remove the measuring
equipment.
10.Adjust:
• throttle cable free play
Refer to "ADJUSTING THE THROTTLE
CABLE FREE PLAY".
Throttle cable free play (at the
flange of the throttle grip)
3 ~ 5 mm (0.12 ~ 0.20 in)
11.Remove:
• vacuum gauge
12.Install:
• side cover (left and right)
• center cover
Refer to "SIDE COVER MOULDINGS AND
LEG SHIELD".
• seat
Refer to "SEAT".
EAS00869
ADJUSTING THE EXHAUST GAS VOLUME
NOTE:
Be sure to set the CO density level to stan-
dard, and then adjust the exhaust gas volume.
1. Turn the main switch to "OFF" and set the
engine stop switch to "
2. Simultaneously
"SELECT" 1 and "RESET" 2 buttons, turn
the main switch to "ON", and continue to
press the buttons for 8 seconds or more.
NOTE:
• All displays on the meter disappear except
the clock and tripmeter displays.
• "dIAG" appears on the tripmeter LCD.
3. Press the "SELECT" 1 button to select the
CO adjustment mode "CO" or the diagnostic
mode "dIAG".
4. After selecting "CO", simultaneously press
the "SELECT" 1 and "RESET" 2 buttons
for 2 seconds or more to execute the selec-
tion.
3 - 19
CHK
ADJ
".
press
and
hold
the

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp500a

Table of Contents