CM Oven Service Manual
CONVECTION ELEMENT
Terminals
Refer to Page 34 to access the convection ele-
ment. To test the element, perform the follow-
ing steps.
1.
Turn off the electrical power to the oven.
2.
Set the ohmmeter to the R x 1 scale.
3.
Disconnect one of the wires from the con-
vection element.
4.
Touch the test leads to the convection
element terminals. The meter should indi-
cate between 15 Ω and 25 Ω.
CONVECTION MOTOR
Refer to Page 36 to access the convection mo-
tor. To test the motor, perform the following
steps.
1.
Turn off the electrical power to the oven.
2.
Set the ohmmeter to the R x 1 scale.
3.
Disconnect one of the wires from the con-
vection motor.
4.
Touch the test leads to the convection
motor terminals. The meter should indi-
cate between 10 Ω and 20 Ω.
Page 58
Lit. No. 94-30-006B
Terminals