REMOVING THE MEAT PROBE JACK
WARNING
Turn off the electrical power going to the
oven before servicing.
CAUTION
When you work on the oven, be careful
when handling the sheet metal parts. There
are sharp edges present and you can cut
yourself if you are not careful.
1.
Turn off the electrical power going to the
oven.
2.
Pull the oven out of its mounting location
just far enough so that you can access the
meat probe jack access panel on the right
side of the oven.
3.
Open the microwave oven door.
4.
Raise the cover on the meat probe jack,
then use a 17 mm (11/16˝) socket, and re-
move the hex nut.
5.
Remove the screw from the meat probe
jack access panel on the right side of the
oven.
6.
7.
Screw
Meat Probe
Jack Access
Panel
Page 37
Remove the piece of insulation that is cov-
ering the meat probe jack.
Pull the meat probe jack and flat washer
out of the cutout and disconnect the two
wires from the terminals.
Ground
(–) Wire
Meat
Probe
Jack
Tech Tips!!
1. Connect the wire with the GND tag on it
to the ground terminal on the meat probe
jack. This terminal is part of the jack's
frame. Be sure to reinstall the flat washer
on the jack.
2. To make it easier when reinstalling the
hex nut on the jack, place the nut inside
the spring cover and close the cover.
Thread the nut onto the jack as far as pos-
sible by turning the cover, and then
tighten it firmly using the socket.