Removing Crossflow Top Cooling Blower - Thermador CM301B Service Manual

Built-in
Table of Contents

Advertisement

Lit. No. 94-30-006B
REMOVING THE CROSSFLOW TOP COOLING BLOWER
WARNING
Turn off the electrical power going to the
oven before servicing.
CAUTION
When you work on the oven, be careful
when handling the sheet metal parts. There
are sharp edges present and you can cut
yourself if you are not careful.
1.
Turn off the electrical power going to the
oven.
2.
Pull the oven out of its mounting location
so that you can access the trim and ple-
num covers.
3.
Remove the trim and top plenum covers
from the oven (see Page 10).
4.
Disconnect the wires from the terminals
of the crossflow top cooling blower.
5.
Remove the two screws from the blower
mounting bracket and remove the blower
from the oven.
WH75
BU-74
SH162
BU-161
WH-164
BU-163
Page 17
CM Oven Service Manual
Bracket Screws
Crossflow Top
Cooling Blower

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cm301wCm302wCm302sCm301sCm302b

Table of Contents