Maintenance
item No.
Setting the transfer cleaning voltage
U107
Description
Sets the cleaning control voltage for transfer belt unit.
Purpose
Change settings if an offset has occurred due to the failure of cleaning the transfer belt.
Setting
1. Press the start key.
2. Select the item to be set.
Display
Belt Clean A (F)
Belt Clean A (H)
Belt Clean B (H)
Belt Clean A(BW)*
*: Displayed by 40/35 ppm model only
Setting: Transfer belt cleaning voltage (printing)
1. Change the value using the cursor up/down keys.
Display
Width<160
160<=Width<220
220<=Width
*: Old and new transfer belt unit
2. Press the start key. The value is set.
Setting: Transfer belt cleaning voltage (using thick paper)
1. Change the value using the cursor up/down keys.
Display
Width<160
160<=Width<220
220<=Width
*: Old and new transfer belt unit
2. Press the start key. The value is set.
Setting: Transfer belt cleaning voltage (paper interval)
1. Change the value using the cursor up/down keys.
Display
Belt Clean B (F)
Belt Clean B (H)
Belt Clean B(BW)* Transfer belt cleaning voltage in
*: Displayed by 40/35 ppm model only
2. Press the start key. The value is set.
Description
Description
Transfer belt cleaning voltage (printing)
Transfer belt cleaning voltage (using thick paper)
Transfer belt cleaning voltage (paper interval)
Transfer belt cleaning voltage in printing monochrome mode
Description
Small sizes (under 160 mm wide)
Medium sizes (160 to under 220 mm
wide)
Large sizes (more than 220mm wide) 0 to 255
Description
Small sizes (under 160 mm wide)
Medium sizes (160 to under 220 mm
wide)
Large sizes (more than 220mm wide) 0 to 255
Description
Transfer belt cleaning voltage
Transfer belt cleaning voltage (using
thick paper)
monochrome mode
2JL/2JJ/2JG/2JD-1
Default setting
Setting
25/25,32/25,
range
32/32 ppm
0 to 255
64/90*
0 to 255
64/90*
51/90*
Default setting
Setting
25/25,32/25,
range
32/32 ppm
0 to 255
51/55*
0 to 255
51/55*
51/55*
Default setting
Setting
25/25,32/25,
range
32/32 ppm
0 to 255
170
0 to 255
110
0 to 255
-
40/35 ppm
85
85
85
40/35 ppm
60
60
60
40/35 ppm
158
104
153
1-3-41