Kyocera KM-C2525E Service Manual page 270

Hide thumbs Also See for KM-C2525E:
Table of Contents

Advertisement

2JL/2JJ/2JG/2JD
(5) Detaching and refitting the LSU cleaning clutch
Follow the procedure below to replace the LSU cleaning clutch.
Procedure
1. Remove the interface cover and right cover
(see page 1-5-4).
2. Remove the rear cover and front left cover 1
(see page 1-5-8).
3. Remove the paper conveying unit, convey-
ing guide and middle guide unit (see page 1-
5-17).
4. Remove the image formation holder (see
page 1-5-24).
5. Pull out cassette 1.
6. Remove two screws and remove the front
cover.
7. Remove the screw and two locking claws,
and then remove the inner left cover.
Leave the connectors kept plugged to the
switches.
8. Remove the screw of transfer high voltage PWB 2.
While unlatching and holding the locking claw upward,
push the transfer high voltage PWB 2 outward.
1-5-38
Front cover
Figure 1-5-83
Inner left cover
Figure 1-5-84
Transfer high voltage PWB 2
Locking claw
Figure 1-5-85
Locking claws

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-c3232eKm-c4035eKm-c3225e

Table of Contents