5.6.3.2.3 Details of Bit 1
It is possible to select the detection time for caarrier disconnection between the DCS signal and TCF signal during
reception.
This bit is available for use when #1 SSSW SW18 Bit0 is set to "1".
If the symptom is not resolved by setting SW18 Bit 0 to "1," set this bit to "1."

5.6.4 Numeric Parameter Settings (NUMERIC Param.)

5.6.4.1 #NUMERIC Param.
No.
010
011
013
No.010
Use it to set the length of time for line connection identification.
If an error occurs often because of the line condition at time of a communication, increase the parameter.
Memo
The line connection recognition time means the period from transmission of dial signal to detection of
significant signal for the transmission end, and the period from transmission of DIS signal to detection of
significant signal for the receiving end.
No.011
Set the T1 timer for the receiver (wait time after DIS transmission starts until a significant signal is received).
If frequent errors occur during reception because of line connection conditions, increase the value of this
parameter.
No.013
Set the maximum receivable time per line of image data when receiving image data. If the other party is a
computer fax and the like, and the image data reception time per line is longer, increase the value of this
parameter to lengthen the maximum receivable time.
Function
Line connection identification time length
T.30 T1 timer (for reception)
Maximum time to receive one line of image
data
T-5-12
Selecting range
0 to 9999 (10ms)
0 to 9999 (10ms)
500 to 3000 (10ms)
Chapter 5
0006-5832
0006-5833
Default
setting
5500
3500
1300
5-41