14.3.6 <011: T.30 T1 timer (for reception)>
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
Set the T1 timer for the receiver (wait time after DIS transmission starts until a significant signal is received).
14.3.7 <013: T.30 EOL timer>
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
Set it so that the 1-line transmission time is longer for reception to prevent reception errors caused by a long data length per line (e.g., computer FAX).
14.3.8 <016: time length to first response at time of fax/tel switchover>
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
Allows setting of the time from seizing the line till pseudo RBT is sent, when the Fax/ Tel switching function is operating.
14.3.9 <017: pseudo RBT signal pattern ON time length><018: pseudo RBT signal pattern OFF time length (short)><019:
pseudo RBT signal pattern OFF time length (long)>
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
Use it to set the pattern of the pseudo RBT signal transmitted at time of a fax/tel switchover.
14.3.10 <020: pseudo CI signal pattern ON time length><021: pseudo CI signal pattern OFF time length (short)><022:
pseudo CI signal pattern OFF time length (long)>
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
Use it to set the pseudo CI signal pattern transmitted at time of a fax/tel switchover.
14.3.11 <023: CNG detention level for fax/tel switchover>
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
Use it to set the CNG detention level for a fax/tel switchover.
14.3.12 <024: pseudo RBT transmission level at time of fax/tel switchover>
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
Use it to set the pseudo transmission level for a fax/tel switchover.
14.3.13 <025: Answering machine connection function signal detection time>
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
Sets the signal detection time for the answering machine connection function operation. When the answering machine connection function is operating, if the func-
tion does not operate normally because the fax does not detect CNG signal sent from the line, raise this parameter to increase the signal detection time.
14.3.14 <027: V.21 low-speed flag preamble identification length>
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
Use it to detect the time of detection after which command analysis is started after detecting V.21 low-speed command preambles continuously for a specific period
of time.

14.4 Scanner Function Settings (SCANNER)

14.4.1 Numeric Parameter Functional configuration

LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
No.
001: - 023:
024:
025:
026:
027: - 030:
031:
032:
033:
034:
035: - 036:
037: - 040:
041:
042:
043:
044:
Download Free Service Manual And Resetter Printer at http://printer1.blogspot.com
Function
Not used
CIS scan position during ADF scanning.
Not used
Distance from the standby position of CIS to the
shading start point.
Not used
Vertical scan start position adjustment
Horizontal scan start position adjustment
Vertical scan magnification correction
Horizontal scan magnification correction
Reader motor speed adjustment
Not used
Vertical scan start position adjustment (scanning
on ADF)
Horizontal scan start position adjustment
(scanning on ADF)
Horizontal scan end position correction
(copy:scanning on ADF)
Horizontal scan end position correction
(superfine:scanning on ADF)
Default
Setting range
385
300-450
22
6-48
35
0-70
115
50-150
32
0-32
32
0-32
555
35
0-70
219
170-270
75
0-200
75
0-200
Chapter 14
Unit
one unit=0.1mm
one unit=0.1mm
one unit=0.1mm
one unit=0.1mm
one unit=0.1%
one unit=0.1%
one unit=0.1mm
one unit=0.1mm
one unit=0.1mm
one unit=0.1mm
0011-4152
0011-4153
0011-4155
0011-4156
0011-4157
0011-4158
0011-4159
0011-4160
0011-4161
0011-4164