14.02 SETUP & CONFIGURATION
Follow these steps for setting up VT100 Mode:
Power off your VIPer and install jumper W22(3-4) to enable VT100 Mode. Note:
VT100 Mode runs on UART1 and UART2.
Connect the communications cable as shown in Diagram 14-1. Note: If you do not
require a full cable for your terminal, you can set up a partial cable by using only the
TXD and RXD lines. The control lines can be ignored by looping them back as shown
in Diagram 14-2.
Power on your VIPer and run VIPer Setup by hitting the CTRL and V keys
simultaneously, before or when you see the message "Press CTRL-V to enter
TEKNOR VIP-UP" at the top of the screen. On the second screen, set the "VT100 &
Serial Download Speed" at 19200 BPS or 9600 BPS.
You must respect this protocol: 8 Bits
If you are running a terminal emulation program, these parameters must be set in it.
VT100 Mode
14-2
No Parity
Echo Off.