Supervisor Utilities - Teknor Industrial Computers VIPer807 Technical Reference Manual

Table of Contents

Advertisement

4.04 SUPERVISOR UTILITIES

The VIPer series incorporates features that are usually not found on commercial PCs.
TEKNOR computers utilize address space 190H, 290H or 390H to enable these special
features. The I/O address is jumper selectable (W21 jumper - Section 3).
TABLE 4-3: Register 190H, 290H or 390H
Bit #
Bit Value
Function:
(Default)
WRITE
0
0
Enable Watchdog
1=enable, R/W bit
1
1
Watchdog activate
1-0-1 to toggle, R/W bit
2
0
Flash VPP enable
RS-485 direction control.
3
0
Refer to Section 5.02 about
RS-485 Serial Port.
4
0
Reserved
5
0
Reserved
6
1
Reserved
7
0
Reserved
F Not all bits are R/W. Therefore, be certain to keep a mirror image of the register
when programming it.
F All bits are 0 after a hardware RESET or power up condition.
F Write the values shown in the "Bit Value (Default)" column if you are unsure.
Installing & Working With System Components
READ
Same
Same
Same
Power Detection Output or
Battery Low output
W22 (7-8) Status
W22 (5-6) Status
W22 (3-4) Status
W22 (1-2) Status
4-6