Diagnostics and System Data

11.4 Diagnostics and System Data

The diagnostics allow you to find the main cause of a trouble or a breakdown of the
machine.
The machine executes self tests to diagnose the system and generates the corres-
ponding reports.
The System Data give data about the status of the machine and the events or errors
occurred in the machine.
Diagnostics
As Supervisor, you can gain access to the diagnostics that follow:
Nb
Diagnostic
1
Ping server
2
Sensors status
3
Advanced feeder
4
Letter opener
5
Dynamic Scale sensors
6
Display
7
Keypad
8
USB ports
9
Serial connectors
Comments
Sends a message to a server (if connected) to
check the line.
Reports the status ([0] or [1]) of the sensors bellow:
Top doc
Start print
Cover
Carriage
Top Seal
[TBD]
[TBD]
Gives access to the tests bellow:
1 Dynamic Scale main motor test
2 Dynamic test
The screen displays, successively and without text,
a red page, a green page, and a blue page.
Displays "Key ok" if the test is correct
Checks the two USB ports (need USB keys).
Checks the COM ports.
11