Disassembly, Reassembly and Lubrication

3-6-24. Disassembling the "Roll Paper Shaft"

1. Remove the 2 screws (BHT (#2), M3x6 (NI)) and detach the "Shaft Paper".
2. Remove the "Slider PNE", "Lever PNE" and "Spring PNE" from the "Cover Shaft Paper".
NOTE: To remove the "Lever PNE", pull it out from the "Slider PNE".
Notes on reassembling:
• Apply FLOIL G-311S to the convex parts (2 places) of the "Lever PNE. (See the mark
the figure.)
• Insert the "Lever PNE" into the "Slider PNE" as shown below.
• Insert the end of the "Spring PNE" ("A") into
"B" into the slit
"B'
[When assembling]
Spring PNE
B'
Cover Shaft Paper
[Lubrication]
FLOIL G-311S
CL-S6621
Cover Shaft Paper
Shaft Paper
" as shown below.
A
Slider PNE
A'
B
Slider PNE
Spring PNE
Lever PNE
Slider PNE
BHT (#2), M3x6 (NI)
"A'
" of the "Slider PNE". Also, insert the projection
[When assembling]
Slider PNE
Lever PNE
3-54
shown in