3.9.6 Control Panel ASSY

(1) Remove four screws "a" from the control panel ASSY.
(2) Pull up the rear end of the control panel ASSY and turn it up slightly.
Note: Do not pull the control panel ASSY away from the machine since it is connected to
the machine with harnesses.
(3) Slide the control panel ASSY slightly to the rear, disconnect the panel-main harness and
touch panel harness* from the main PCB, and release them from their cable guides.
(4) Disconnect the LCD flat cable from the main PCB.
Note: After disconnecting the flat cable, check that it is not damaged at its end or short-
circuited. When connecting the flat cable, do not insert it at an angle. After insertion, check
again that it is not at an angle.
(5) Models with touch panel: Release the grounding wire by removing screw "b" and remove
it from the cable guides.
Upper cover
Panel-main
harness
Cable guide
LT cover
Assembling Notes:
• When connecting the panel-main harness to the main PCB, route the taped section through
the cable guide on the upper cover to prevent the harness from getting crushed between the
control panel ASSY and the upper cover.
• After mounting the control panel ASSY, check that there is no gap between the front end of
the control panel ASSY and that of the upper cover.
"a"
"a"
3-81
*For models with touch panel
"a"
Control panel ASSY
"a"
LCD flat cable
Cable guides
Touch panel harness*
"a": Taptite, cup B M3x10
"b": Taptite, cup S M3x6*
"b" *
Grounding wire*
Cable guides
(3_048)
Confidential