Temperature; Aidc Mode; Supplies Replace - Konica Minolta bizhub c20 Service Manual

Hide thumbs Also See for bizhub c20:
Table of Contents

Advertisement

14. SERVICE MODE
14.4.22

TEMPERATURE

• To adjust the fusing heating temperature individually for each paper type so as to
Function
ensure good fusing performance that varies with varying environmental conditions.
Use
• When fusing performance is poor, or wax streak or offset occurs when the type of
paper is changed or environmental conditions change.
• Use this function when curled paper, or paper misfeed as a result of the curled paper,
occurs under varying environmental conditions or depending on the type of paper
used.
PLAIN PAPER: -10 °C to 0 °C (step: 5 °C)
TRANSPARENCY: -10 °C to 0 °C (step: 5 °C)
Adjustment
THICK: -10 °C to 0 °C (step: 5 °C)
Range
ENVELOPE: -10 °C to 0 °C (step: 5 °C)
Adjustment
If fusing performance is poor, increase the setting.
Instructions
If wax streaks occur, decrease the setting.
If offset is poor, decrease the setting.
If curling of the paper occurs, decrease the setting.
Setting
1. Select [TEMPERATURE] and press the Select key.
/procedure
2. Select the type of paper and press the Select key.
3. Select desired setting value with the up key /down key
14.4.23

AIDC MODE

• Sets the frequency of image stabilization that is performed when the main power
Function
switch is turned ON or the machine returns from sleep mode.
Use
• MODE1: Always performs image stabilization when the main power switch is turned
• MODE2: Reduces the frequency of image stabilization that is performed when the
Setting
• The default setting is MODE1.
/procedure
14.4.24

SUPPLIES REPLACE

A. TRANSFER BELT
Function
• Resets the transfer belt counter.
Use
• To use when the transfer belt has been replaced.
1. Select [SUPPLIES REPLACE] → [TRANSFER BELT].
Setting
/procedure
2. Press the Select key.
3. Press the Select key and reset the counter.
B. FUSER UNIT
Function
• Resets the fuser unit counter.
Use
• To use when the fuser unit has been replaced.
1. Select [SUPPLIES REPLACE] → [FUSER UNIT].
Setting
/procedure
2. Press the Select key.
3. Press the Select key and reset the counter.
210
ON or the machine returns from sleep mode. (Standard mode)
main power switch is turned ON or the machine returns from sleep mode.
(Low mode)
"MODE1"
Field Service Ver. 1.0 Sep. 2008
and press the Select key.
MODE2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magicolor 4695mf

Table of Contents