Soft Switch: #02 - Konica Minolta bizhub c20 Service Manual

Hide thumbs Also See for bizhub c20:
Table of Contents

Advertisement

Field Service Ver. 1.0 Sep. 2008
15.3.2

SOFT SWITCH: #02

Bit No.
Designation
Time between phase
8
C to phase D signal in
V.17
Example:
7
Image
EOP
Header TX selection
6
open to user
5
Reserved
4
3
Transmit RTN signal
level criteria
2
1
Sent N.G page
• Bit 1: N.G indicate our side detected RTN signal from other end. In this case machine
can resend the same page up to three or just one time, and this use for G3 mode
only.
• Bit 2-3: In G3 mode, if error line for each page, machine will send RTN instead of RTN,
in this case, some machine will resend the same page again. The retry times
depend on other end.
• Bit 6: If this bit set to "0", the header select function can not change by user, only
changeable by serviceman in service mode.
Function
RX
70 ms
Insensitivity
Bit No. 8
0
Bit No. 7
0
0: No
1: Yes
Reserved
Percentage of error line
Bit No. 3
Bit No. 2
0: Send N.G page and up to 3 times for that page
1: Not re-send that N.G page for G3 mode
15. SOFT SWITCH set
120 ms
180 ms
60 ms
0
1
1
1
0
1
10%
20%
25%
15%
0
0
1
1
0
1
0
1
Initial
Setting
Bit
HEX
0
0
0
0
0
0
0
0
0
0