Konica Minolta bizhub c20 Service Manual page 420

Hide thumbs Also See for bizhub c20:
Table of Contents

Advertisement

Field Service Ver. 1.0 Sep. 2008
Code
00BC
Modem can not ready within 10 seconds after entering primary channel in V.34.
00BD
Can not detect correct V.21 or JM signal after detected FSK frequency.
00BE
Remote side no document to be polled after V8 handshaking.
00BF
Capability no match.
00C0
Remote side disconnect before entering primary channel in V.34.
At phase-D, transmitting units out EOP 3 times consecutively, but receive no answer from
00C1
receiving unit.
00C2
Remote side disconnect after sending out V.8 CM signal.
00C4
After sending MPS signal, the received is not one of MCF, RTN, PIP, PIN, RTP, DCN.
00C5
Received DCN signal after sending MPS signal.
00C9
At phase-D, sending MPS 3 times consecutively, but no answer from receiving unit.
00CA
After sending EOP signal, the received is not one of MCF, RTN, PIP, PIN, PRI-EOP, DCN.
00CB
After sending EOP signal, the received is DCN signal.
00CC
After sending EOM signal, the received is not one of MCF, RTN, PIP, PIN, RTP, DCN.
00CD
At phase-D, transmitting units out EOM 3 times consecutively, but receive no answer.
00CE
At phase-D, transmitting units out EOM, but receive DCN.
00CF
Received incorrect signal after sending DTC signal for V.34 polling.
00D0
Received ERR signal after sending EOR_NULL.
00D1
Received incorrect response after sending PPS_EOP signal in V.34.
00D2
Received DCN after sending PPS_EOP signal.
00D3
Received DCN after sending PPS_NULL signal.
00D4
Received DCN after sending PPS_EOM signal.
00D5
T5 timeout.
00D8
Can not detect correct phase 3 signal for polling within 25 seconds.
00D9
Can not detect correct phase 3 signal after detect silence after phase 2.
00DA
Can not detect phase 4 signal within 30 seconds or remote side hang up over 6 seconds.
00DB
Can not received any T.30 signal within 15 seconds within phase 4.
00DC
Received T.30 signal in phase 4 other than DCS, DIS or DTC.
00DE
Remote side no SUB capability in V.34.
00E0
At phase-D, transmitting units out PPS_NULL 3 times consecutively but receive not answer.
00E1
Received incorrect response after sending PPS_NULL.
00E2
Can not receive any response in RR response procedure after sending PPS_NULL.
00E4
At phase-D, transmitting units out PPS_MPS 3 times consecutively but receive no answer.
00E5
Received incorrect response after sending PPS_MPS.
00E6
Can not receive any response in RR response procedure after sending PPS_MPS.
00E7
Received DCN after sending PPS_MPS.
00E8
At phase-D, transmitting units out PPS_EOP 3 times consecutively but receive no answer.
00E9
Receive PIN signal after sent last page three times.
00EA
Can not receive any response in RR response procedure after sending PPS_EOP.
00EB
At phase-D, transmitting units out PPS_EOM 3 times consecutively but receive no answer.
00EC
Received incorrect response after sending PPS_EOM.
00ED
Can not receive any response in RR response procedure after sent out PPS_EOM.
Possible Causes of Error.
21. FAX error
375

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magicolor 4695mf

Table of Contents