Safety Features (If Fitted, See Specifications Table); Maintenance Schedule; Warnings - SDMO HX 3000 Generating Set User And Maintenance Manual

Hide thumbs Also See for HX 3000:
Table of Contents

Advertisement

Available languages

Available languages

4.3. Switching off
When the generating set is turned off, the engine continues to give off heat.
Appropriate ventilation should be provided after the generating set is turned off.
To stop the generating set urgently, place the engine switch on "OFF" or "О".
Warning
Take the plugs out of the sockets and allow the engine to run without any charge for 1 to 2 minutes.
Place the engine switch (no. 10, fig. A) on "OFF" or "О" and the set will stop.
Close the fuel tap (no. 14, fig. A).

5. Safety features (if fitted, see specifications table)

5.1. Oil cut-out
This mechanism is designed to prevent any damage to the motor resulting from lack of oil in the motor sump. It automatically cuts out
the motor. If the motor stops and will not restart, check the motor oil level before looking for any other cause of the problem.
5.2. Circuit breaker
The electrical circuit of the set is protected by several magnetothermal, differential or thermal cut-out switches. Any overload and/or
short circuits cause the supply of electrical energy to be cut.

6. Maintenance schedule

6.1. Reminder of use
The maintenance interval frequency and the operations to be carried out are outlined in the maintenance programme.
However, it should be added that it is the environment in which the generating set is operating which determines this programme.
Accordingly, if the set is used in extreme conditions, shorter intervals between maintenance procedures should be adopted.
These maintenance schedules apply only to generating sets running on fuel and oil, that conform to the specifications given in this
booklet.
6.2. Maintenance table
carry out the maintenance procedures
item
Engine oil
Air filter
Sediment bowl
Spark plug
Spark arrester
Valve clearance
Strainer and petrol tank
Cleaning the generating set
Fuel line
Note: * This procedure should be carried out by one of our registered agents
(1) : Perform air filter maintenance more frequently for operation in dusty locations.
at whichever
deadline is reached first
Check the level
Change
Check
Clean
Clean
Check / clean
Clean
Check / adjust
Clean
Check (replace if necessary)
Each time it is
First month
used
or after the
first 20 hours
Every 3
Every 6
months or
months or
50 hours
100 hours
• (1)
Every 2 years (*)
Every 12
months or
300 hours
• (*)
• (*)

Advertisement

Table of Contents
loading