7-2-1-5 Timeout
The timeout setting for the handshaking acknowledgment from host PC, if
scanner did not receive acknowledgement from the host PC, the warning
sound will be active. This function is particularly useful for some application
which host PC takes longer response time.
Configuration Range
0 ~ 4 minutes 15 sec
Procedure:
(A) Scan "Enter" barcode
(B) Scan "Timeout" barcode
(C) Scan parameters from
Hexadecimal / Decimal table
(D) Scan "OK" barcode
(E) Scan "End" barcode
ENTER
*/$%ENT*
7. General Configuration Setting
*1072*
Unit
1 sec
Example:
If configuration is 2 sec, the
parameter value is 2 sec / 1 sec = 2
92
Default Setting
3 sec
*ZEND*
End