7- 9 Good Read Time
7-9 Good Read Time
This enables to set the scanning duration time for reading the same barcode
label, this function only available when the trigger mode is set in "Continue" or
"Momentary" or "Alternate" mode.(Note: when the configuration is set as
"0" or "00", it means, no waiting time needed. User can scan the same
barcode label without any delay time).
Procedure:
(A) Scan "Enter" barcode
(B) Scan "Good Read Time" barcode
(C) Scan Scan parameters from
Hexadecimal / Decimal table
(D) Scan "OK" barcode
(E) Scan "End" barcode
Note: this configuration is only applicable when the scanner is in USB
cable mode.
ENTER
*/$%ENT*
*8112*
Configuration Range
0 ~ 25 sec
7. General Configuration Setting
Unit
Default Setting
0.1 sec
0.5 sec
Example:
If configuration is 1 sec, the
parameter value is 1 sec / 0.1 sec =
10
109
End