6) Electric system
6.1)
Check of wiring
-
Inspect all cable connectors for tight fit and good contact.
-
Inspect all ground connections for corrosion and security, repair as required.
-
Inspect plug connections between pick-up cable, electronic module, charg-
ing and shorting cables for corrosion and security, repair as required.
-
Inspect plug connections between electronic module and ignition coils for
security, wear and corrosion.
-
Verify plug connections of generator cables with rectifier-regulator and
connections of all cables on rectifier-regulator for good contact, tight fit and
corrosion, repair as required.
-
Inspect grounding cables for tight fit and corrosion, repair as required.
-
Verify shielding of cable assemblies for damage, for ground contact and
security.
-
Inspect all 8 ignition cables to spark plug connector for damage and tight fit.
Inspect resistor plug connector for tight fit on spark plug. Repair or replace as
necessary.
Effectivity: 912 Series
AIRCRAFT ENGINES
MAINTENANCE MANUAL
12-00-00
page 36
Rev. 1, Jan. 01/2002