9) Battery; 10) Capacitor (Option Electric Fuel Pump); 11) Starting Equipment At The Electronic Modules (Optional Extra) - Rotax 912 ULS 3 Installation Manual

Hide thumbs Also See for 912 ULS 3:
Table of Contents

Advertisement

17.3.9) Battery

17.3.10) Capacitor (Option electrical fuel pump)
17.3.11) Easy start function on the electronic module (optional)
Effectivity: 912 Series
Edition 1 / Rev. 1
BRP-Powertrain
INSTALLATION MANUAL
See Fig. 67.
■ CAUTION:
To warrant reliable engine start use a battery of at least
16 Ah capacity.
See Fig. 67.
■ CAUTION:
To warrant reliable operation of the electrical fuel
pump the use of capacitor of at least 22 000 μF / 25 V
is necessary.
See Fig. 67 and 79/1.
In order to use the easy start function the relevant connections to the
starter relays and ignition switch need to be made.
The start function can be used for aircraft, which have an engine start
problem in cold conditions.
◆ NOTE:
In addition also a modified fly wheel hub is offered,
which aids improved starting.
Fig. 79/1