Enter/Exit Programming Mode
Maxicode Length Control
This feature specifies either variable length decoding or fixed length decoding for this
symbology.
Variable Length:
Fixed Length:
DEFAULT
$CMXLC01(CR)
Maxicode Length Control = Fixed Length
Maxicode
Specifies one of the bar code lengths for
label length if in
Characters can be set from 0001 to 0145 characters in increments of 0001 (pad with zeroes).
See
page 253
$CMXL1
Select Maxicode Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
198
For variable length decoding, a minimum and maximum length may be set.
For fixed length decoding, two different lengths may be set.
Set Length 1
Variable Length
Mode, or the first fixed length if in Fixed Length Mode.
for detailed instructions on setting this feature.
0001 = Length 1 is 1 Character
DEFAULT
$CMXLC00(CR)
Maxicode Length Control = Variable Length
Maxicode Length
Control. Length 1 is the minimum
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code
at left followed by the digits from the Alphanumeric
Appendix E, Keypad
characters in
desired character(s). End by scanning the ENTER/EXIT
bar code again.
~
CANCEL
2D Symbologies
representing your
Gryphon™ I GFS4400