Enter/Exit Programming Mode
Symbologies

MSI Length Control

This feature specifies either variable length decoding or fixed length decoding for the
MSI symbology.
For variable length decoding, a minimum and maximum length may be
Variable Length:
set.
For fixed length decoding, two different lengths may be set.
Fixed Length:
$CMSLC00(CR)
DEFAULT
MSI Length Control = Variable Length
$CMSLC01(CR)
MSI = Fixed Length