Datalogic Gryphon I GFS4400 Product Reference Manual page 223

Fixed mount area imager bar code reader
Hide thumbs Also See for Gryphon I GFS4400:
Table of Contents

Advertisement

Description
Restore Current Interface (Custom) Default Configuration
RS232-STD
USB-COM
RS232-Wincor-Nixdorf
USB-KBD
USB-KBD-ALT
USB KBD-APPLE
Description
Baud Rate
Parity
Data Bits
Stop Bits
Handshaking Control
Product Reference Guide
INTERFACE SELECTION COMMANDS
To read a particular parameter setting from the reader, send the
read parameter command without any value. The reader will
respond with its currently configured value.
The Read Application Software Release command is a direct com-
mand that does not require entering Service Mode.
RS-232 ONLY PARAMETERS
1200
2400
4800
9600
19200
38400
57600
115200
none
even
odd
7
8
1
2
RTS
RTS/CTS
RTS/Xon/Xoff
RTS On/CTS
RTS/CTS Scan Control
Command
HA00
HA05
HA47
HA12
HA35
HA2B
HA2C
Parameter
Value
R2BA
00
01
02
03
04
05
06
07
R2PA
00
01
02
R2DA
00
01
R2ST
00
01
R2HC
00
R2HC
01
R2HC
02
R2HC
03
R2HC
04
221