Datalogic Gryphon I GFS4400 Product Reference Manual

Datalogic Gryphon I GFS4400 Product Reference Manual

Fixed mount area imager bar code reader
Hide thumbs Also See for Gryphon I GFS4400:
Table of Contents

Advertisement

Gryphon I GFS4400
Fixed Mount Area Imager
Bar Code Reader

Product Reference Guide

UNGLAUBE
GmbH
*
Obere Hauptstraße 42A
*
84072 Au i. d. Hallertau
Tel. 08752 / 86917-0
*
Fax 08752 / 86917-22
*
www.unglaube.de
*
kontakt@unglaube.de

Advertisement

Table of Contents
loading

Summary of Contents for Datalogic Gryphon I GFS4400

  • Page 1: Product Reference Guide

    Gryphon I GFS4400 Fixed Mount Area Imager Bar Code Reader Product Reference Guide UNGLAUBE GmbH Obere Hauptstraße 42A 84072 Au i. d. Hallertau Tel. 08752 / 86917-0 Fax 08752 / 86917-22 www.unglaube.de kontakt@unglaube.de...
  • Page 2 Datalogic representative. Electronic versions may either be downloadable from the Datalogic website (www.datalogic.com) or provided on appropriate media. If you visit our web- site and would like to make comments or suggestions about this or other Datalogic publications, please let us know via the "Contact Datalogic" page.
  • Page 3: Table Of Contents

    About this Manual ......................................9 Overview ..................................................9 Manual Conventions ............................................10 References ........................................10 Technical Support ......................................10 Datalogic Website Support ..........................................10 Reseller Technical Support ..........................................10 Telephone Technical Support ..........................................10 About the Reader ......................................11 Programming the Reader .................................... 11 Configuration Methods ............................................11...
  • Page 4 Contents USB-OEM Device Usage ........................................48 Transmit Labels in Code 39 Format ..................................49 Interface Options ..........................................49 Data Format .................................... 51 Global Prefix/Suffix ...................................... 52 Global AIM ID ........................................ 53 Set AIM ID Individually for GS1-128 .......................................55 Label ID .......................................... 56 Label ID: Pre-Loaded Sets ..........................................56 Individually Set Label ID .............................................57 Label ID Control ..........................................57 Label ID Symbology Selection −...
  • Page 5 Contents Multiple Labels Ordering by Code Length ................................92 Symbologies ................................... 93 1D Code Selection ......................................93 DISABLE ALL SYMBOLOGIES ..............................94 CODE EAN/UPC .................................... 95 Coupon Control ..........................................95 UPC-A ..............................................96 UPC-A Enable/Disable ........................................96 UPC-A Check Character Transmission ..................................96 Expand UPC-A to EAN-13 ......................................97 UPC-A Number System Character Transmission ..............................97 UPC-A 2D Component ........................................98 UPC-E ......................................
  • Page 6 Contents Code 39 LaPoste Enable/Disable .................................... 125 CODE 39 PZN ....................................125 Code 39 PZN Enable/Disable ....................................125 CODE 128 ....................................126 Code 128 Enable/Disable ......................................126 Expand Code 128 to Code 39 ....................................126 Code 128 Check Character Transmission ................................127 Code 128 Function Character Transmission ..............................
  • Page 7 Contents ABC Codabar Enable/Disable ....................................157 ABC Codabar Concatenation Mode ..................................157 ABC Codabar Dynamic Concatenation Timeout .............................. 158 ABC Codabar Force Concatenation ..................................159 CODE 11 ......................................160 Code 11 Enable/Disable ......................................160 Code 11 Check Character Calculation .................................. 160 Code 11 Check Character Transmission ................................
  • Page 8 Contents China Sensible Code Set Length 2 ..................................193 Data Matrix .........................................194 Data Matrix Enable / Disable ......................................... 194 Data Matrix Square/Rectangular Style ....................................... 194 Data Matrix Length Control ........................................... 195 Data Matrix Set Length 1 ......................................195 Data Matrix Set Length 2 ......................................196 Maxicode ........................................197 Maxicode Enable / Disable ..........................................
  • Page 9 Contents Digital Output ..............................................269 Scanning Active Time ............................................270 Aiming Duration Time ............................................. 271 Multiple Labels Ordering by Code Symbology ..................................272 TECHNICAL SPECIFICATIONS..............................275 Imager Labeling ......................................280 Aiming System ..............................................280 LED and Beeper Indications ..................................281 Button and LED Status ............................................. 281 Indicators ................................................
  • Page 10 Contents NOTES Gryphon™ I GFS4400...
  • Page 11: Introduction

    Chapter 1 Introduction About this Manual This Product Reference Guide (PRG) is provided for users seeking advanced technical information, including connection, programming, maintenance and specifications. The Quick Reference Guide (QRG) and other publications associated with this product are downloadable free of charge from the website listed on the back cover of this manual. Overview Chapter 1, (this chapter) presents information about manual conventions, and an overview of the...
  • Page 12: Manual Conventions

    Telephone Technical Support If you do not have internet or email access, you may contact Datalogic technical support at (541) 349-8283 or check the back cover of your manual for more contact information. Gryphon™ I GFS4400...
  • Page 13: About The Reader

    It is intended to be an easy integration by system designers with little expertise in scanning technology. Unlike currently available products, the GFS4400 uses the latest and fastest imaging technology and offers Datalogic’s Green Spot for targeting and good read feedback.
  • Page 14 Introduction Programming the Reader Datalogic Aladdin™ Programming can alternatively be performed using the Datalogic Aladdin™ Configuration application. Aladdin™ is a multi-platform utility program providing a quick and user-friendly configuration method via the RS-232/USB-COM interface. It communicates to the device through a user-friendly graphical interface running on a PC. Selected configuration commands are sent to the reader over the selected communication interface using a serial or USB cable, or they can be printed as bar codes to be scanned.
  • Page 15: Setup

    Setup Unpacking Check carefully to ensure the reader and any accessories ordered are present and undamaged. If any damage occurred during shipment, contact Datalogic Technical Support. Information is shown on page 10 KEEP THE PACKAGING. Should the unit ever require service, it should be returned in its original shipping container.
  • Page 16: Attaching Reader To Host

    Setup Attaching Reader to Host Attaching Reader to Host RS-232 Serial Connection Turn off power to the terminal/PC and connect the reader to the terminal/PC serial port via the RS-232 cable as shown in . If the terminal will not support POT (Power Off the Figure 1 Terminal) to supply reader power, use the approved power supply (AC Adapter).
  • Page 17: Interface Selection

    Interface Selection Setup Interface Selection Since your scanner should have shipped with the correct interface cable (RS-232 or USB), the interface type should already be defined. If you need to change the interface type, go to Table 1 and scan the appropriate bar code in that section. starting on page 16 Each reader model will support one of the following sets of host interfaces: GFS4450-9 Model...
  • Page 18 $P,HA13,P(CR) starting on page 25 RS-232 for use with OPOS/UPOS/JavaPOS Select RS-232 OPOS $P,HA47,P(CR) USB Com to simulate RS-232 standard interface Select USB-COM-STD a. Download the correct USB Com driver from www.adc.datalogic.com USB-OEM FEATURES Set USB-OEM $P,HA45,P(CR) Interface USB-OEM Features...
  • Page 19 Interface Selection Setup KEYBOARD FEATURES $P,HA35,P(CR) USB Keyboard with standard key encoding Select USB Keyboard Set KEYBOARD $P,HA2C,P(CR) Interface USB Keyboard for Apple computers Features starting on page 37 Select USB-KBD-APPLE $P,HA2B,P(CR) USB Keyboard with alternate key encoding Select USB Alternate Keyboard Product Reference Guide...
  • Page 20: Custom Configuration Settings

    Setup Custom Configuration Settings Custom Configuration Settings Configure Interface Settings If your installation requires you to select options to customize your reader, turn to the appropriate section for your interface type in "Configuration Using Bar Codes" starting on page 21 •...
  • Page 21: Resetting The Product Configuration To Defaults

    Custom Configuration Settings Setup Resetting the Product Configuration to Defaults Restore Custom Defaults If you aren’t sure what programming options are in your imager, or you’ve changed some options and want to restore the Custom Default Configuration that may have been saved in the scanner, scan the Restore Custom Default Configuration bar code below.
  • Page 22 Setup Custom Configuration Settings NOTES Gryphon™ I GFS4400...
  • Page 23: Configuration Using Bar Codes

    Chapter 3 Configuration Using Bar Codes This and following sections provide programming bar codes to configure your reader by changing the default settings. For details about additional methods of programming, see "Configuration Methods" on page You must first enable your reader to read bar codes in order to use this Setup, starting on page 13 section.
  • Page 24 Enter/Exit Programming Mode You must first enable your reader to read bar codes in order to use this Setup, starting on page 13 section. If you have not done this, go to complete the appropriate procedure. To program features: 1. Scan the ENTER/EXIT PROGRAMMING bar code, available at the top of each pro- gramming page, when applicable.
  • Page 25: Global Interface Features

    Enter/Exit Programming Mode GLOBAL INTERFACE FEATURES The following interface features are configurable by all interface types. Host Commands — Obey/Ignore This option specifies whether the reader will obey or ignore host commands. When set to ignore, the reader will ignore all host commands except for those necessary for: •...
  • Page 26 Enter/Exit Programming Mode NOTES Gryphon™ I GFS4400...
  • Page 27: Rs-232 Only Interface

    RS-232 ONLY INTERFACE on page 26 on page 27 on page 27 ARITY on page 28 ANDSHAKING ONTROL on page 29 Use the programming bar codes in this section if modifications to the standard RS-232 interface settings are necessary to meet your system’s requirements. Additional settings which apply to both the RS-232 and USB interfaces are available in the next section, "RS- 232/USB-Com Interfaces"...
  • Page 28: Baud Rate

    Enter/Exit Programming Mode RS-232 Only Interface Baud Rate page 244 for information on this feature. $CR2BA00(CR) Baud Rate = 1200 $CR2BA01(CR) Baud Rate = 2400 $CR2BA02(CR) Baud Rate = 4800 $CR2BA03(CR) DEFAULT Baud Rate = 9600 $CR2BA04(CR) Baud Rate = 19,200 $CR2BA05(CR) Baud Rate = 38,400 $CR2BA06(CR)
  • Page 29: Data Bits

    RS-232 Only Interface Enter/Exit Programming Mode Data Bits This parameter allows the reader to interface with devices requiring a 7-bit or 8-bit ASCII protocol for sending and receiving data. $CR2DA00(CR) 7 Data Bits $CR2DA01(CR) DEFAULT 8 Data Bits Stop Bits Set the number of stop bits to match host device requirements.
  • Page 30: Parity

    Enter/Exit Programming Mode RS-232 Only Interface Parity This feature specifies parity required for sending and receiving data. Select the parity type according to host device requirements. See page 244 for more information. $CR2PA00(CR) DEFAULT Parity = None $CR2PA01(CR) Parity = Even $CR2PA02(CR) Parity = Odd Gryphon™...
  • Page 31: Handshaking Control

    RS-232 Only Interface Enter/Exit Programming Mode Handshaking Control page 244 for more information about this feature. $CR2HC00(CR) DEFAULT Handshaking Control = RTS $CR2HC01(CR) Handshaking Control = RTS/CTS $CR2HC02(CR) Handshaking Control = RTS/XON/XOFF $CR2HC03(CR) Handshaking Control = RTS On/CTS $CR2HC04(CR) Handshaking Control = RTS/CTS Scan Control Product Reference Guide...
  • Page 32: Rs-232/Usb-Com Interfaces

    RS-232/USB-COM INTERFACES NTERCHARACTER ELAY on page 31 ASCII BEL on page 31 OT ON on page 32 ACK NAK O PTIONS on page 32 ACK C HARACTER on page 33 NAK C HARACTER on page 33 ACK NAK T IMEOUT ALUE on page 34 ACK NAK R...
  • Page 33: Intercharacter Delay

    RS-232/USB-Com Interfaces Enter/Exit Programming Mode Intercharacter Delay This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments.
  • Page 34: Beep On Not On File

    Enter/Exit Programming Mode RS-232/USB-Com Interfaces Beep On Not on File This option enables/disables the action of the reader to sound a three beep sequence upon receiving a Not-On-File (NOF) host command. $CBPNF00(CR) Beep On Not On File = Disable $CBPNF01(CR) DEFAULT Beep On Not On File = Enable ACK NAK Options...
  • Page 35: Ack Character

    RS-232/USB-Com Interfaces Enter/Exit Programming Mode ACK Character This setting specifies an ASCII character or hex value to be used as the ACK character. ASCII characters or any hex value from 0 to 0xFF can be selected. See page 246 for more information. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal Data Bits operation of these characters.
  • Page 36: Ack Nak Timeout Value

    Enter/Exit Programming Mode RS-232/USB-Com Interfaces ACK NAK Timeout Value This option specifies the amount of time the reader waits for an ACK character from the host following label transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15 seconds) in 200ms increments. A selection of 0 disables the timeout. page 248 for more information on setting this feature.
  • Page 37: Ack Nak Error Handling

    RS-232/USB-Com Interfaces Enter/Exit Programming Mode ACK NAK Error Handling This feature specifies the method the reader uses to handle receive errors detected while waiting for an ACK character from the host. $CR2EH00(CR) DEFAULT ACK NAK Error Handling = Ignore Errors Detected $CR2EH01(CR) ACK NAK Error Handling = Process Error as Valid ACK Character...
  • Page 38: Disable Character

    Enter/Exit Programming Mode RS-232/USB-Com Interfaces Disable Character Specifies the value of the RS-232 host command used to disable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with Data Bits normal operation of these characters.
  • Page 39: Usb Keyboard Settings

    USB KEYBOARD SETTINGS OUNTRY on page 38 ONTROL HARACTERS on page 42 NTERCODE ELAY on page 43 TATE on page 43 USB K EYBOARD PEED on page 44 USB K EYBOARD UMERIC EYPAD on page 45 Use the programming bar codes in this chapter to select options for USB Keyboard Interface.
  • Page 40: Country Mode

    Enter/Exit Programming Mode USB Keyboard Settings Country Mode This feature specifies the country/language supported by the keyboard. Several languages are supported: $CKBCO00(CR) DEFAULT Country Mode = U.S. $CKBCO01(CR) Country Mode = Belgium $CKBCO02(CR) Country Mode = Britain $CKBCO11(CR) Supports only the interfaces listed in the Country Mode feature description.
  • Page 41 USB Keyboard Settings Enter/Exit Programming Mode Country Mode (continued) $CKBCO04(CR) Country Mode = France $CKBCO13(CR) Supports only the interfaces listed in the Country Mode fea- ture description. Country Mode = French Canadian $CKBCO05(CR) Country Mode = Germany $CKBCO0D(CR) Supports only the interfaces listed in the Country Mode fea- ture description.
  • Page 42 Enter/Exit Programming Mode USB Keyboard Settings Country Mode (continued) $CKBCO14(CR) Supports only the interfaces listed in the Country Mode feature description. Country Mode = Lithuanian $CKBCO07(CR) Country Mode = Norway $CKBCO12(CR) Supports only the interfaces listed in the Country Mode feature description.
  • Page 43 USB Keyboard Settings Enter/Exit Programming Mode Country Mode (continued) $CKBCO09(CR) Country Mode = Spain $KBCO0A(CR) Country Mode = Sweden $CKBCO0B(CR) Supports only the interfaces listed in the Country Mode feature description. Country Mode = Switzerland Product Reference Guide...
  • Page 44: Send Control Characters

    Enter/Exit Programming Mode USB Keyboard Settings Send Control Characters This feature specifies how the reader transmits ASCII control characters to the host. Reference Appendix G, Scancode Tables for more information about control characters. Options are as follows: Control Character 00 : Characters from 00 to 0x1F are sent as control character Ctrl+Keys, special keys are located from 0x80 to 0xA1.
  • Page 45: Intercode Delay

    USB Keyboard Settings Enter/Exit Programming Mode Intercode Delay Specifies the delay between labels transmitted to the host for this interface. The selectable range for this feature is from 0 to 99 seconds. page 252 in “References” for detailed information and examples for setting this feature. To configure this feature, scan the ENTER/EXIT PROGRAM- $CKBID MING MODE bar code above, then the bar code at left fol-...
  • Page 46: Usb Keyboard Speed

    Enter/Exit Programming Mode USB Keyboard Settings USB Keyboard Speed This option specifies the USB poll rate for a USB keyboard. This feature applies ONLY to the USB Keyboard interface. $CKBSP01(CR) DEFAULT USB Keyboard Speed = 1ms $CKBSP02(CR) USB Keyboard Speed = 2ms $CKBSP03(CR) USB Keyboard Speed = 3ms $CKBSP04(CR)
  • Page 47: Usb Keyboard Numeric Keypad

    USB Keyboard Settings Enter/Exit Programming Mode USB Keyboard Speed (continued) $CKBSP07(CR) USB Keyboard Speed = 7ms $CKBSP08(CR) USB Keyboard Speed = 8ms $CKBSP09(CR) USB Keyboard Speed = 9ms $CKBSP0A(CR) USB Keyboard Speed = 10ms USB Keyboard Numeric Keypad This option Controls whether numeric characters will be sent using standard keys or the numeric keypad.
  • Page 48 Enter/Exit Programming Mode USB Keyboard Settings NOTES Gryphon™ I GFS4400...
  • Page 49: Usb-Oem Interface

    USB-OEM INTERFACE USB-OEM D EVICE SAGE on page 48 39 F RANSMIT ABELS IN ORMAT on page 49 NTERFACE PTIONS on page 49 Feature settings for USB interfaces differ depending upon which host type the reader will be connected with. Use the feature settings in this chapter to specifically configure for the USB- OEM interface.
  • Page 50: Usb-Oem Device Usage

    Enter/Exit Programming Mode USB-OEM Interface USB-OEM Device Usage The USB-OEM protocol allows for the reader to be identified as one of two different types of bar code scanners. Depending on what other scanners you may already have connected to a USB-OEM POS, you may need to change this setting to enable all devices to communicate.
  • Page 51: Transmit Labels In Code 39 Format

    USB-OEM Interface Transmit Labels in Code 39 Format This feature enable/disables translation to Code 39 before transmitting label data to a USB- OEM host. Only the symbology identifier is modified for the translation. The data is not converted to Code 39 or verified to be valid for Code 39. Options are: Code 39 Format: Translate the following symbologies to Code 39:...
  • Page 52 USB-OEM Interface NOTES Gryphon™ I GFS4400...
  • Page 53: Data Format

    DATA FORMAT LOBAL REFIX UFFIX on page 52 AIM ID LOBAL on page 53 AIM ID I GS1-128 NDIVIDUALLY FOR on page 55 ABEL starting on page 56 • Label ID: Pre-Loaded Sets • Individually Set Label ID • Label ID Control •...
  • Page 54: Global Prefix/Suffix

    Enter/Exit Programming Mode Data Format Global Prefix/Suffix This option sets up to 20 characters each from the set of ASCII characters or any hex value from 00 to FF. The characters may be added as a prefix (in a position before the bar code data, also called a header) and/or as a suffix (in a position following the bar code data, also called a footer).
  • Page 55: Global Aim Id

    Data Format Enter/Exit Programming Mode Global AIM ID This feature enables/disables addition of AIM IDs for all symbology types. AIM label identifiers (as opposed to custom characters you select yourself as with label identifiers) can be included with scanned bar code data. See Table 2 on page 3-53 for a listing of AIM IDs.
  • Page 56 Enter/Exit Programming Mode Data Format DATABAR EXPANDED COMPOSITE DATABAR LIMITED DATABAR LIMITED COMPOSITE DATA MATRIX EAN128 EAN128 COMPOSITE EAN13 EAN13 P2 EAN13 P5 EAN13 COMPOSITE EAN8 EAN8 P2 EAN8 P5 EAN8 COMPOSITE FOLLET 2OF5 I2OF5 IATA INDUSTRIAL 2OF5 INDUSTRIAL 2OF5 ISBN ISBT128 CONCAT ISSN...
  • Page 57: Set Aim Id Individually For Gs1-128

    Data Format Enter/Exit Programming Mode Set AIM ID Individually for GS1-128 This feature configures a Label ID individually for the GS1-128 symbology and the programming for this works the same way as Label ID. See Label ID: Set Individually Per Symbology, starting on page 260 for detailed instructions on setting this feature.
  • Page 58: Label Id

    Data Format Label ID A Label ID is a customizable code of up to three ASCII characters (convert to Hex using the ASCII Chart on the inside back cover of this manual), used to identify a bar code symbology type. It can be appended previous to or following the transmitted bar code data depending upon how this option is enabled.
  • Page 59: Individually Set Label Id

    Data Format Enter/Exit Programming Mode Individually Set Label ID This feature configures a Label ID individually for a single symbology. To set, first define whether you want it as a prefix or suffix by scanning a label below. Then turn to Label ID Symbology Selection •...
  • Page 60: Label Id Symbology Selection − 1D Symbologies

    Enter/Exit Programming Mode Data Format Label ID Symbology Selection 1D Symbologies − This option selects the symbology for which a Label ID is to be configured. See "Label ID" on page 56 or page 260 in “References” for more detailed instructions. If less than the expected string of 3 characters are selected, scan the ENTER/ EXIT bar code twice to accept the selection and exit Programming Mode.
  • Page 61 Data Format Enter/Exit Programming Mode Label ID Symbology Selection − 1D Symbologies (continued) $CCCID $C35ID Set EAN 13 P5 Label ID Character(s) Set Code 39 CIP Label ID Character(s) $CXCID $C8BID Set EAN 8 Label ID Character(s) Set GS1 DataBar Expanded Composite Label ID Character(s) $C8MID $CU8ID...
  • Page 62 Enter/Exit Programming Mode Data Format Label ID Symbology Selection − 1D Symbologies (continued) $CXBID $CGBID Set GS1 DataBar Expanded Label ID Character(s) Set GTIN 8 Label ID Character(s) $CLPID $CIAID Set IATA Industrial 2 of 5 Label ID Character(s) Set LaPoste Code 39 Label ID Character(s) $CPMID $CMSID Set IMB Postal Code Label ID Character(s)
  • Page 63 Data Format Enter/Exit Programming Mode Label ID Symbology Selection − 1D Symbologies (continued) $CPBID $CPZID Set PZN Code Label ID Character(s) Set Postnet BB Label ID Character(s) $CPRID $CAMID Set Royal Postal Code Label ID Character(s) Set UPC-A Composite Label ID Character(s) $CS2ID $CA2ID Set Standard 2 of 5 Label ID Character(s)
  • Page 64 Enter/Exit Programming Mode Data Format Label ID Symbology Selection 2D Symbologies − $CAZID $CMXID Set Maxicode Label ID Character(s) Set Aztec Label ID Character(s) $CCSID $CP4ID Set China Sensible Label ID Character(s) Set PDF 417 Label ID Character(s) $CMIID $CCFID Set Codablock F Label ID Character(s) Set Micro PDF 417 Label ID Character(s) $CDMID...
  • Page 65: No Read Message

    Data Format Enter/Exit Programming Mode No Read Message This feature Enables/Disables the No Read Message feature. When Disabled, nothing is sent if the trigger is pressed and released when no code has been decoded during a reading phase. Otherwise, the No Read String is sent. (See "No Read String"...
  • Page 66: Code Verifier

    Enter/Exit Programming Mode Data Format CODE VERIFIER This feature allows the scanner to verify that all codes read and decoded match a defined string saved in its memory. It is valid when in On Line, Serial On Line, Automatic and Automatic (Object Sense) Operating Modes.
  • Page 67: Match String

    Data Format Enter/Exit Programming Mode Match String This feature allows you to define the string to be used as the match code for Code Verification. The Match String must be configured to include start/stop characters and check digits if their transmission is enabled.
  • Page 68: Label Transmit Mode

    (Phase Off). $CLFTX00\r Phase Off $CLFTX01\r DEFAULT On Decode Advanced Formatting: User Label Edit Advanced formatting is available to create user label edit scripts. See the Datalogic Aladdin configuration application or contact Technical Support. Gryphon™ I GFS4400...
  • Page 69: Case Conversion

    Data Format Enter/Exit Programming Mode Case Conversion This feature allows conversion of the case of all alphabetic characters to upper or lower case. Case conversion affects ONLY scanned bar code data, and does not affect Label ID, Prefix, Suffix, or other appended data. $CLFCA00(CR) DEFAULT Case Conversion = Disable (no case conversion)
  • Page 70 Enter/Exit Programming Mode Data Format NOTES Gryphon™ I GFS4400...
  • Page 71: Digital Output

    DIGITAL OUTPUT Digital Output only pertains to the GFS4450-9 RS232 interface. CTIVATION VENT on page 70 EACTIVATION VENT on page 71 EACTIVATION IMEOUT on page 71 CTIVATION TATE on page 72 See “References” starting on page 254 for more information about Digital Output. Use the programming barcodes in this chapter to select options for Digital Outputs.
  • Page 72: Activation Event

    Enter/Exit Programming Mode Digital Output Activation Event Defines the event activating the output. $COUA100\r DEFAULT Disable $COUA101\r Good Read $COUA102\r No Read $COUA103\r Wrong Code Gryphon™ I GFS4400...
  • Page 73: Deactivation Event

    Digital Output Enter/Exit Programming Mode Deactivation Event Defines the event deactivating the output. See "Wrong Code String" on page 264 “References” for more information about this feature. $COUD100\r DEFAULT Disable $COUD101\r Timeout $COUD102\r Reading Phase Active Deactivation Timeout When Timeout is the selected Deactivation Event, this specifies the maximum duration of the output pulse.
  • Page 74: Activation State

    Enter/Exit Programming Mode Digital Output Activation State Determines the active state of the output. $COUL100\r DEFAULT Closed $COUL101\r Open Gryphon™ I GFS4400...
  • Page 75: Reading Parameters

    READING PARAMETERS OUBLE IMEOUT REQUENCY on page 74 on page 76 EEPER NDICATORS on page 75 ENGTH on page 77 OWER LERT on page 75 OLUME on page 78 LED D HEN TO NDICATE on page 75 URATION on page 79 on page 76 SCANNING FEATURES PERATING...
  • Page 76: Double Read Timeout

    Enter/Exit Programming Mode Reading Parameters Double Read Timeout Double Read Timeout specifies the minimum time between consecutive good reads of labels of the same symbology and data. This prevents a double read of the same label. If the unit reads a label and sees the same label again within the specified timeout, the second read is ignored.
  • Page 77: Led And Beeper Indicators

    Reading Parameters Enter/Exit Programming Mode LED AND BEEPER INDICATORS Power On Alert Disables or enables the indication (from the Beeper) that the reader is receiving power. $CBPPU00(CR) Power On Alert = Disable (No Audible Indication) $CBPPU01(CR) DEFAULT Power On Alert = Power-up Beep Good Read: When to Indicate This feature specifies when the reader will provide indication (beep and/or flash its green LED) upon successfully reading a bar code.
  • Page 78: Good Read Beep Type

    Enter/Exit Programming Mode Reading Parameters Good Read Beep Type Specifies whether the good read beep has a mono or bitonal beep sound. $CBPTY00(CR) DEFAULT Good Read Beep Type = Mono $CBPTY01(CR) Good Read Beep Type = Bitonal Good Read Beep Frequency Adjusts the good read beep to sound at a selectable low, medium or high frequency, selectable from the list below.
  • Page 79: Good Read Beep Length

    Reading Parameters Enter/Exit Programming Mode Good Read Beep Length $CBPLE06(CR) Good Read Beep Length = 60 msec $CBPLE08(CR) DEFAULT Good Read Beep Length = 80 msec $CBPLE0A(CR) Good Read Beep Length = 100 msec $CBPLE0C(CR) Good Read Beep Length = 120 msec $CBPLE0E(CR) Good Read Beep Length = 140 msec $CBPLE10(CR)
  • Page 80: Good Read Beep Volume

    Enter/Exit Programming Mode Reading Parameters Good Read Beep Volume Selects the beeper volume (loudness) upon a good read beep. There are three selectable volume levels. $CBPVO00CR) Good Read Beep Volume = Beeper Off $CBPVO01CR) Good Read Beep Volume = Low $CBPVO02CR) Good Read Beep Volume = Medium $CBPVO03CR)
  • Page 81: Good Read Led Duration

    Reading Parameters Enter/Exit Programming Mode Good Read LED Duration This feature specifies the amount of time that the Good Read LED remains on following a good read. The good read LED on time can be set within a range of 100 milliseconds to 25,500 milliseconds (0.1 to 25.5 seconds) in 100ms increments.
  • Page 82: Scanning Features

    Enter/Exit Programming Mode Reading Parameters SCANNING FEATURES Operating Mode Selects the reader’s scan operating mode. See page 268 in “References” for descriptions. $CSNRM00\r On Line $CSNRM01\r Serial On Line $CSNRM02\r Automatic $CSNRM03\r DEFAULT Automatic (Object Sense) Gryphon™ I GFS4400...
  • Page 83: Phase Off Event

    Reading Parameters Enter/Exit Programming Mode Phase Off Event $CSPTO00\r DEFAULT Trigger Stop $CSPTO01\r Timeout $CSPTO02\r Trigger Stop - Timeout Phase Off Timeout Timeout can be set within a range of 1second to 255 seconds in 1 second intervals. To configure this feature scan the ENTER/EXIT PROGRAMMING $CSNET MODE barcode above, then the barcode at left, followed by the digits (in hex) from the Alphanumeric characters in...
  • Page 84: Serial Start Character

    Enter/Exit Programming Mode Reading Parameters Serial Start Character page 268 in “References” for more information. To configure this feature scan the ENTER/EXIT PROGRAMMING $CSTON MODE barcode above, then the barcode at left, followed by the digits (in hex) from the Alphanumeric characters in Appendix E, Keypad representing your desired charac- ter(s).
  • Page 85: Presentation Mode Indication

    Reading Parameters Enter/Exit Programming Mode Presentation Mode Indication This operation is useful for indicating when the reader is in Automatic/Triggered Object Sense Operating Mode. If enabled, the blue indicator will blink when Presentation Mode scanning is active. $CSMFL00(CR) DEFAULT Presentation Mode Indication = Disable $CSMFL01(CR) Presentation Mode Indication = Enable Manual Trigger Control...
  • Page 86: Central Code Only

    Enter/Exit Programming Mode Reading Parameters Central Code Only Specifies the ability of the reader to decode labels only when they are close to the center of the aiming pattern. This allows the reader to accurately target labels when they are placed close together, such as on a pick sheet.
  • Page 87: Illumination On Time

    Reading Parameters Enter/Exit Programming Mode Illumination On Time Defines the amount of time illumination is kept ON after a label is decoded. If an object is detected before Illumination ON expires, the timer is refreshed with the Object Gone timeout value.
  • Page 88: Presentation Illumination Control

    Enter/Exit Programming Mode Reading Parameters Presentation Illumination Control Controls the illumination status while the reading mode is Automatic Trigger Object Sense Operating Mode and the reader is attempting to detect objects. $CSMIL00(CR) DEFAULT Illumination Control = OFF $CSMIL01(CR) Illumination Control = ON $CSMIL02(CR) Illumination Control = Dim Aiming Pointer...
  • Page 89: Aiming Duration Timer

    Reading Parameters Enter/Exit Programming Mode Aiming Duration Timer Specifies the frame of time the aiming pointer remains on after decoding a label, when in On Line or Serial On Line mode.The range for this setting is from 1 to 255 seconds in 1-second increments.
  • Page 90: Mobile Phone Mode

    Enter/Exit Programming Mode Reading Parameters Mobile Phone Mode This mode is useful for scanning bar codes displayed on a mobile phone. Other options for this feature can be configured using the Datalogic Aladdin application. $CSNPE00(CR) Mobile Phone Mode = Disable $CSNPE01(CR)
  • Page 91: Partial Label Reading Control

    Reading Parameters Enter/Exit Programming Mode Partial Label Reading Control Enable/Disable the option to ignore partial labels to be read within the boundary of the field of view. IPPL00 Partial Label Reading Control = Disable IPPL01 DEFAULT Partial Label Reading Control = Enable Mirror Reading Mode Enable/Disable the ability to decode the mirror image of a bar code label.
  • Page 92: Decode Negative Image

    Decode Negative Image = Disable $P,CI$PVR01,P\r Decode Negative Image = Enable Image Capture For information and a list of options for Image Capture, use the Datalogic Aladdin configuration application, available for free download from the Datalogic website. Gryphon™ I GFS4400...
  • Page 93: Multiple Label Reading

    Reading Parameters MULTIPLE LABEL READING When the reader’s aiming system is activated by a trigger push or other method (depending on the mode), it then acquires and processes each image in the area in front of it (the Volume). In this case, the scanner stops processing the image once it decodes a label.
  • Page 94: Multiple Labels Ordering By Code Symbology

    Reading Parameters Multiple Labels Ordering by Code Symbology This feature allows you to specify the order multiple labels are transmitted by symbology type, when Multiple Labels per Frame is enabled. See page 272 in “References” for detailed information on setting this feature. To configure this feature, scan the ENTER/EXIT PROGRAM- $CSNMS MING MODE bar code above, then the bar code at left fol-...
  • Page 95: Symbologies

    SYMBOLOGIES 1D Code Selection The reader supports the following 1D symbologies (bar code types). See "2D Symbologies" starting on page 185 for 2D bar codes. Symbology-dependent options are included in each chapter. • Disable All Symbologies on page • GS1-128 on page •...
  • Page 96: Disable All Symbologies

    Enter/Exit Programming Mode Symbologies DISABLE ALL SYMBOLOGIES Use this feature to disable all symbologies. 1. Scan the ENTER/EXIT PROGRAMMING Mode bar code. 2. Scan the Disable All Symbologies bar code. 3. Complete the programming sequence by scanning the ENTER/EXIT PROGRAM- MING bar code.
  • Page 97: Code Ean/Upc

    Symbologies Enter/Exit Programming Mode CODE EAN/UPC Coupon Control This feature is used to control the reader’s method of processing coupon labels. $CCPLC00(CR) Coupon Control = Allow all coupon bar codes to be decoded $CCPLC01(CR) DEFAULT Coupon Control = Enable only UPCA coupon decoding $CCPLC02(CR) Coupon Control = Enable only GS1 DataBar™...
  • Page 98: Upc-A

    Enter/Exit Programming Mode Symbologies UPC-A The following options apply to the UPC-A symbology. UPC-A Enable/Disable When disabled, the reader will not read UPC-A bar codes. $CABEN00(CR) UPC-A = Disable $CABEN01(CR) DEFAULT UPC-A = Enable UPC-A Check Character Transmission Enable this option to transmit the check character along with UPC-A bar code data. $CABCT00(CR) UPC-A Check Character Transmission = Don’t Send $CABCT01(CR)
  • Page 99: Expand Upc-A To Ean-13

    Symbologies Enter/Exit Programming Mode Expand UPC-A to EAN-13 Expands UPC-A data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13. $CAB3B00(CR) DEFAULT UPC-A to EAN-13 = Don’t Expand $CAB3B01(CR) UPC-A to EAN-13 = Expand UPC-A Number System Character Transmission This feature enables/disables transmission of the UPC-A number system character.
  • Page 100: Upc-A 2D Component

    Enter/Exit Programming Mode Symbologies UPC-A 2D Component This feature enables/disables a requirement that a 2D label component be decoded when a base label of this symbology is decoded. $CAB2D00(CR) DEFAULT EAN-13 2D Component = Disable (2D component not required) $CAB2D01(CR) EAN-13 2D Component = 2D component must be decoded UPC-E...
  • Page 101: Upc-E Check Character Transmission

    Symbologies Enter/Exit Programming Mode UPC-E Check Character Transmission Enable this option to transmit the check character along with UPC-E bar code data. $CEBCT00(CR) UPC-E Check Character Transmission = Don’t Send $CEBCT01(CR) DEFAULT UPC-E Check Character Transmission = Send UPC-E 2D Component This feature enables/disables a requirement that a 2D label component be decoded when a base label for this symbology is decoded.
  • Page 102: Expand Upc-E To Ean-13

    Enter/Exit Programming Mode Symbologies Expand UPC-E to EAN-13 Expands UPC-E data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13. $CEB3B00(CR) DEFAULT UPC-E to EAN-13 = Don’t Expand $CEB3B01(CR) UPC-E to EAN-13 = Expand Expand UPC-E to UPC-A Expands UPC-E data to the UPC-A data format.
  • Page 103: Upc-E Number System Character Transmission

    Symbologies Enter/Exit Programming Mode UPC-E Number System Character Transmission This feature enables/disables transmission of the UPC-E system number character. $CEBNS00(CR) UPC-E Number System Character = Do not transmit $CEBNS01(CR) DEFAULT UPC-E Number System Character = Transmit GTIN FORMATTING This feature enables/disables the ability to convert UPC-E, UPC-A, EAN 8, and EAN 13 labels into the GTIN 14-character format.
  • Page 104: Ean 13 (Jan 13)

    Enter/Exit Programming Mode Symbologies EAN 13 (JAN 13) The following options apply to the EAN 13 (Jan 13) symbology. EAN 13 Enable/Disable When disabled, the reader will not read EAN 13/JAN 13 bar codes. $C3BEN00(CR) EAN 13 = Disable $C3BEN01(CR) DEFAULT EAN 13 = Enable EAN 13 Check Character Transmission...
  • Page 105: Ean-13 Flag 1 Character

    Symbologies Enter/Exit Programming Mode EAN-13 Flag 1 Character Enables/disables transmission of an EAN/JAN13 Flag1 character. The Flag 1 character is the first character of the label. $C3BF100(CR) EAN-13 Flag 1 Char= Don’t transmit $C3BF101(CR) DEFAULT EAN-13 Flag 1 Char= Transmit EAN-13 ISBN Conversion This option enables/disables conversion of EAN 13/JAN 13 Bookland labels starting with 978 to ISBN labels.
  • Page 106: Ean-13 2D Component

    Enter/Exit Programming Mode Symbologies EAN-13 2D Component This feature enables/disables a requirement that a 2D label component be decoded when a base label of this symbology is decoded. $C3B2D00(CR) DEFAULT EAN-13 2D Component = Disable (2D component not required) $C3B2D01(CR) EAN-13 2D Component = 2D component must be decoded ISSN...
  • Page 107: Ean 8 (Jan 8)

    Symbologies Enter/Exit Programming Mode EAN 8 (JAN 8) The following options apply to the EAN 8 (Jan 8) symbology. EAN 8 Enable/Disable When disabled, the reader will not read EAN 8/JAN 8 bar codes. $C8BEN00(CR) EAN 8 = Disable $C8BEN01(CR) DEFAULT EAN 8 = Enable EAN 8 Check Character Transmission...
  • Page 108: Expand Ean 8 To Ean 13

    Enter/Exit Programming Mode Symbologies Expand EAN 8 to EAN 13 Enable this option to expand EAN 8/JAN 8 labels to EAN 13/JAN 13. $C8B3B00(CR) DEFAULT Expand EAN 8 to EAN 13 = Disable $C8B3B01(CR) Expand EAN 8 to EAN 13 = Enable EAN 8 2D Component This feature enables/disables a requirement that a 2D label component be decoded when a base label for this symbology is decoded.
  • Page 109: Upc/Ean Global Settings

    Symbologies Enter/Exit Programming Mode UPC/EAN GLOBAL SETTINGS This section provides configuration settings for UPC-A, UPC-E, EAN 13 and EAN 8 symbologies, and affects all of these unless otherwise marked for each feature description. UPC/EAN Price Weight Check This feature enables/disables calculation and verification of price/weight check digits. $CPWEN00(CR) DEFAULT Price Weight Check = Disabled...
  • Page 110: Upc/Ean Quiet Zones

    Enter/Exit Programming Mode Symbologies UPC/EAN Quiet Zones This feature specifies the number of quiet zones for UPC/EAN labels. Quiet zones are blank areas at the ends of a bar code, typically 10 times the width of the narrowest bar or space in the label.
  • Page 111: Add-Ons

    Symbologies Enter/Exit Programming Mode ADD-ONS Contact Customer Support for advanced programming of optional and conditional add-ons. Optional Add-ons The reader can be enabled to optionally read the following add-ons (supplementals): If a UPC/EAN base label and an add-on are both decoded, the reader will transmit the base label and add-on.
  • Page 112: Optional Add-On Timer

    Enter/Exit Programming Mode Symbologies Optional Add-On Timer This option sets the time the reader will look for an add-on when an add-on fragment has been seen and optional add-ons are enabled. (Also see "Optional GS1-128 Add-On Timer" on page 113.) $CADOT01(CR) Optional Add-on Timer = 10ms $CADOT02(CR)
  • Page 113 Symbologies Enter/Exit Programming Mode Optional Add-On Timer — cont. $CADOT06(CR) Optional Add-on Timer = 60ms $CADOT07(CR) DEFAULT Optional Add-on Timer = 70ms $CADOT0A(CR) Optional Add-on Timer = 100ms $CADOT0C(CR) Optional Add-on Timer = 120ms $CADOT0E(CR) Optional Add-on Timer = 140ms $CADOT10(CR) Optional Add-on Timer = 160ms Product Reference Guide...
  • Page 114 Enter/Exit Programming Mode Symbologies Optional Add-On Timer — cont. $CADOT12(CR) Optional Add-on Timer = 180ms $CADOT14(CR) Optional Add-on Timer = 200ms $CADOT16(CR) Optional Add-on Timer = 220ms $CADOT18(CR) Optional Add-on Timer = 240ms $CADOT1A(CR) Optional Add-on Timer = 260ms $CADOT1C(CR) Optional Add-on Timer = 280ms $CADOT1E(CR) Optional Add-on Timer = 300ms...
  • Page 115: Optional Gs1-128 Add-On Timer

    Symbologies Enter/Exit Programming Mode Optional GS1-128 Add-On Timer This option sets the timer expiration value to read the added part after reading the linear EAN/ UPC part. For UPC/EAN add-ons other than those of that type, see "Optional Add-On Timer" on page 110. $CADUT00(CR) DEFAULT Optional GS1-128 Add-On Timer = Disable...
  • Page 116 Enter/Exit Programming Mode Symbologies Optional GS1-128 Add-On Timer — cont. $CADUT06(CR) Optional GS1-128 Add-On Timer = 60ms $CADUT07(CR) Optional GS1-128 Add-On Timer = 70ms $CADUT0A(CR) Optional GS1-128 Add-On Timer = 100ms $CADUT0C(CR) Optional GS1-128 Add-On Timer = 120ms $CADUT0E(CR) Optional GS1-128 Add-On Timer = 140ms $CADUT10(CR) Optional GS1-128 Add-On Timer = 160ms Gryphon™...
  • Page 117 Symbologies Enter/Exit Programming Mode Optional GS1-128 Add-On Timer — cont. $CADUT12(CR) Optional GS1-128 Add-On Timer = 180ms $CADUT14(CR) Optional GS1-128 Add-On Timer = 200ms $CADUT16(CR) Optional GS1-128 Add-On Timer = 220ms $CADUT18(CR) Optional GS1-128 Add-On Timer = 240ms $CADUT1A(CR) Optional GS1-128 Add-On Timer = 260ms $CADUT1C(CR) Optional GS1-128 Add-On Timer = 280ms $CADUT1E(CR)
  • Page 118: Code 39

    Enter/Exit Programming Mode Symbologies CODE 39 The following options apply to the Code 39 symbology. Code 39 Enable/Disable $CC3EN00(CR) Code 39 = Disable $CC3EN01(CR) DEFAULT Code 39 = Enable Code 39 Check Character Calculation Enable this option to enables/disables calculation and verification of an optional Code 39 check character.
  • Page 119: Code 39 Check Character Transmission

    Symbologies Enter/Exit Programming Mode Code 39 Check Character Calculation — cont. $CC3CC04(CR) Code 39 Check Character Calculation = Enable Italian Post Check $CC3CC08(CR) Code 39 Check Character Calculation = Enable Daimler Chrysler Check Code 39 Check Character Transmission Enable this option to transmit the check character along with Code 39 bar code data. $CC3CT00(CR) Code 39 Check Character Transmission = Don’t Send $CC3CT01(CR)
  • Page 120: Code 39 Start/Stop Character Transmission

    Enter/Exit Programming Mode Symbologies Code 39 Start/Stop Character Transmission Enable this option to enable/disable transmission of Code 39 start and stop characters $CC3SS00(CR) DEFAULT Code 39 Start/Stop Character Transmission = Don’t Transmit $CC3SS01(CR) Code 39 Start/Stop Character Transmission = Transmit Code 39 Full ASCII Enables/disables the translation of Code 39 characters to Code 39 full-ASCII characters.
  • Page 121: Code 39 Quiet Zones

    Symbologies Enter/Exit Programming Mode Code 39 Quiet Zones This feature specifies the number of quiet zones for Code 39 labels. Quiet zones are blank areas at the ends of a bar code, typically 10 times the width of the narrowest bar or space in the label. $CC3LO02(CR) Code 39 Quiet Zones = Quiet Zones on two sides $CC3LO03(CR)
  • Page 122: Code 39 Set Length 1

    Enter/Exit Programming Mode Symbologies Code 39 Set Length 1 This feature specifies one of the bar code lengths for Code 39 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode.
  • Page 123: Code 39 Set Length 2

    Symbologies Enter/Exit Programming Mode Code 39 Set Length 2 This feature specifies one of the bar code lengths for Code 39 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode.
  • Page 124: Trioptic Code

    Enter/Exit Programming Mode Symbologies TRIOPTIC CODE The following options apply to the Trioptic symbology. Trioptic Code Enable/Disable $CCTEN00(CR) DEFAULT Trioptic Code = Disable $CCTEN01(CR) Trioptic Code = Enable CODE 32 (ITAL PHARMACEUTICAL CODE) The following options apply to the Code 32 (Italian Pharmaceutical Code) symbology. Code 32 Enable/Disable When disabled, the reader will not read Code 32 bar codes.
  • Page 125: Code 32 Feature Setting Exceptions

    Symbologies Enter/Exit Programming Mode Code 32 Feature Setting Exceptions The following features are set for Code 32 by using these Code 39 settings: "Code 39 Quiet Zones" on page 119 "Code 39 Length Control" on page 119 "Trioptic Code" on page 122 Code 32 Check Char Transmission Enable this option to transmit the check character along with Code 32 bar code data.
  • Page 126: Code 39 Cip (French Pharmaceutical)

    Enter/Exit Programming Mode Symbologies CODE 39 CIP (FRENCH PHARMACEUTICAL) The following options apply to the Code 39 CIP symbology. Code 39 CIP Enable/Disable Enables/Disables ability of the reader to decode Code 39 CIP labels. $CCCEN00(CR) DEFAULT Code 39 CIP = Disable $CCCEN01(CR) Code 39 CIP = Enable CODE 39 DANISH PPT...
  • Page 127: Code 39 Laposte

    Symbologies Enter/Exit Programming Mode CODE 39 LAPOSTE The following options apply to the Code 39 LaPoste symbology. Code 39 LaPoste Enable/Disable Enables/disables the ability of the scanner to decode Code39 La Poste labels. $CLPEN00(CR) DEFAULT Code 39 LaPoste = Disable $CLPEN01(CR) Code 39 LaPoste = Enable CODE 39 PZN...
  • Page 128: Code 128

    Enter/Exit Programming Mode Symbologies CODE 128 The following options apply to the Code 128 symbology. Code 128 Enable/Disable When disabled, the reader will not read Code 128 bar codes. $CC8EN00(CR) Code 128 = Disable $CC8EN01(CR) DEFAULT Code 128 = Enable Expand Code 128 to Code 39 This feature enables/disables expansion of Code 128 labels to Code 39 labels.
  • Page 129: Code 128 Check Character Transmission

    Symbologies Enter/Exit Programming Mode Code 128 Check Character Transmission Enable this option to transmit the check character along with Code 128 bar code data. $CC8CT00(CR) DEFAULT Code 128 Check Character Transmission = Don’t Send $CC8CT01(CR) Code 128 Check Character Transmission = Send Code 128 Function Character Transmission Enables/disables transmission of Code128 function characters 1, 2, 3, and 4.
  • Page 130: Code 128 Sub-Code Exchange Transmission

    Enter/Exit Programming Mode Symbologies Code 128 Sub-Code Exchange Transmission Enables/disables the transmission of “Sub-Code Exchange” characters (NOT transmitted by standard decoding). $CC8SC00(CR) DEFAULT Code 128 Sub-Code Exchange Transmission = Disable $CC8SC01(CR) Code 128 Sub-Code Exchange Transmission = Enable Code 128 Quiet Zones This feature specifies the number of quiet zones for Code 128 labels.
  • Page 131: Code 128 Length Control

    Symbologies Enter/Exit Programming Mode Code 128 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 128 symbology. See page 253 for more information. $CC8LC00(CR) DEFAULT Code 128 Length Control = Variable Length $CC8LC01(CR) Code 128 Length Control = Fixed Length Product Reference Guide...
  • Page 132: Code 128 Set Length 1

    Enter/Exit Programming Mode Symbologies Code 128 Set Length 1 Specifies one of the bar code lengths for Code 128 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode.
  • Page 133: Code 128 Set Length 2

    Symbologies Enter/Exit Programming Mode Code 128 Set Length 2 This feature specifies one of the bar code lengths for Code 128 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode.
  • Page 134: Gs1-128

    Enter/Exit Programming Mode Symbologies GS1-128 The following options apply to the GS1-128 symbology. (Also known as USS-128, GS1-128, GTIN-128, UCC-128, EAN-128.) GS1-128 Enable This option enables/disables the ability of the reader to translate GS1-128 labels to the GS1-128 data format. Options are: •...
  • Page 135: Code Isbt 128

    Symbologies Enter/Exit Programming Mode CODE ISBT 128 The following options apply to the ISBT 128 symbology. ISBT 128 Concatenation Use this option to enable/disable ISBT128 concatenation of 2 labels. $CI8CE00(CR) DEFAULT ISBN 128 Concatenation = Disable $CI8CE01(CR) ISBN 128 Concatenation = Enable ISBT 128 Force Concatenation When enabled, this feature forces concatenation for ISBT.
  • Page 136: Isbt 128 Concatenation Mode

    Enter/Exit Programming Mode Symbologies ISBT 128 Concatenation Mode Specifies the concatenation mode between Static and Dynamic. ISBT 128 Concate- This option is only valid when ISBT 128 Concatenation is enabled (see " nation" on page 133 $CI8CM00CR) DEFAULT ISBT 128 Concatenation Mode = Static $CI8CM01CR) ISBT 128 Concatenation Mode = Dynamic Gryphon™...
  • Page 137: Isbt 128 Dynamic Concatenation Timeout

    $CI8DT64(CR) ISBT 128 Dynamic Concatenation Timeout = 1 second ISBT 128 Advanced Concatenation Options To set up pairs of label types for concatenation, use the Datalogic Aladdin configuration page 10 application or contact Datalogic Technical Support, as described on Product Reference Guide...
  • Page 138: Interleaved 2 Of 5 (I 2 Of 5)

    Enter/Exit Programming Mode Symbologies INTERLEAVED 2 OF 5 (I 2 OF 5) The following options apply to the I 2 of 5 symbology. I 2 of 5 Enable/Disable When disabled, the reader will not read I 2 of 5 bar codes. $CI2EN00(CR) DEFAULT I 2 of 5 = Disable...
  • Page 139: I 2 Of 5 Check Character Calculation

    Symbologies Enter/Exit Programming Mode I 2 of 5 Check Character Calculation This option enables/disables calculation and verification of an optional I 2 of 5 check character. Combinations of these settings are possible via the Aladdin configuration utility, or contact Technical Support. $CI2CC00(CR) DEFAULT I 2 of 5 Check Character Calculation = Disable...
  • Page 140: I 2 Of 5 Check Character Transmission

    Enter/Exit Programming Mode Symbologies I 2 of 5 Check Character Transmission Enable this option to transmit the check character along with I 2 of 5 bar code data. $CI2CT00(CR) I 2 of 5 Check Character Transmission = Don’t Send $CI2CT01(CR) DEFAULT I 2 of 5 Check Character Transmission = Send I 2 of 5 Length Control...
  • Page 141: I 2 Of 5 Set Length 1

    Symbologies Enter/Exit Programming Mode I 2 of 5 Set Length 1 This feature specifies one of the bar code lengths for I 2 of 5 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode.
  • Page 142: I 2 Of 5 Set Length 2

    Enter/Exit Programming Mode Symbologies I 2 of 5 Set Length 2 This feature specifies one of the bar code lengths for I 2 of 5 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode.
  • Page 143: Interleaved 2 Of 5 Cip Hr

    Symbologies Enter/Exit Programming Mode INTERLEAVED 2 OF 5 CIP HR The following options apply to the Interleaved 2 of 5 CIP HR symbology. Interleaved 2 of 5 CIP HR Enable/Disable Enables/Disables ability of reader to decode Interleaved 2 of 5 CIP HR labels. $CCHEN00(CR) DEFAULT Interleaved 2 of 5 CIP HR = Disable...
  • Page 144: Standard 2 Of 5

    Enter/Exit Programming Mode Symbologies STANDARD 2 OF 5 The following options apply to the Standard 2 of 5 symbology. Standard 2 of 5 Enable/Disable When disabled, the reader will not read Standard 2 of 5 bar codes. $C2SEN00(CR) DEFAULT Standard 2 of 5 = Disable $C2SEN01(CR) Standard 2 of 5 = Enable Standard 2 of 5 Check Character Calculation...
  • Page 145: Standard 2 Of 5 Check Character Transmission

    Symbologies Enter/Exit Programming Mode Standard 2 of 5 Check Character Transmission This feature enables/disables transmission of an optional Standard 2 of 5 check character. $CS2CT00(CR) Standard 2 of 5 Check Character Transmission = Don’t Send $CS2CT01(CR) DEFAULT Standard 2 of 5 Check Character Transmission = Send Standard 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the Standard 2 of 5 symbology.
  • Page 146: Standard 2 Of 5 Set Length 1

    Enter/Exit Programming Mode Symbologies Standard 2 of 5 Set Length 1 This feature specifies one of the bar code lengths for Standard 2 of 5 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode.
  • Page 147 Symbologies Enter/Exit Programming Mode Standard 2 of 5 Set Length 2 This feature specifies one of the bar code lengths for Standard 2 of 5 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode.
  • Page 148: Industrial 2 Of 5

    Enter/Exit Programming Mode Symbologies INDUSTRIAL 2 OF 5 The following options apply to the Industrial 2 of 5 symbology. Industrial 2 of 5 Enable/Disable Enables/Disables ability of reader to decode Industrial 2 of 5 labels. $CU2EN00(CR) DEFAULT Industrial 2 of 5 = Disable $CU2EN01(CR) Industrial 2 of 5 = Enable Industrial 2 of 5 Check Character Calculation...
  • Page 149: Industrial 2 Of 5 Check Character Transmission

    Symbologies Enter/Exit Programming Mode Industrial 2 of 5 Check Character Transmission Enables/disables transmission of an Industrial 2 of 5 check character. $CU2CT00(CR) Industrial 2 of 5 Check Character Transmission = Disable $CU2CT01(CR) DEFAULT Industrial 2 of 5 Check Character Transmission = Enable Industrial 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the Industrial 2 of 5 symbology.
  • Page 150: Industrial 2 Of 5 Set Length 1

    Enter/Exit Programming Mode Symbologies Industrial 2 of 5 Set Length 1 This feature specifies one of the bar code lengths for Industrial 2 of 5 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode.
  • Page 151 Symbologies Enter/Exit Programming Mode Industrial 2 of 5 Set Length 2 This feature specifies one of the bar code lengths for Industrial 2 of 5 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode.
  • Page 152: Code Iata

    Enter/Exit Programming Mode Symbologies CODE IATA The following options apply to the IATA symbology. IATA Enable/Disable Enables/Disables the ability of the reader to decode IATA labels. $CIAEN00(CR) DEFAULT IATA = Disable $CIAEN01(CR) IATA = Enable IATA Check Character Transmission Enables/Disables calculation and verification of an optional Industrial 2 of 5 check character. $CIACT00(CR) IATA Check Character Transmission = Disable $CIACT01(CR)
  • Page 153: Codabar

    Symbologies Enter/Exit Programming Mode CODABAR The following options apply to the Codabar symbology. Codabar Enable/Disable When disabled, the reader will not read Codabar bar codes. $CCBEN00(CR) DEFAULT Codabar = Disable $CCBEN01(CR) Codabar = Enable Codabar Check Character Calculation Enable this option to enables/disables calculation and verification of an optional Codabar check character.
  • Page 154: Codabar Check Character Transmission

    Enter/Exit Programming Mode Symbologies Codabar Check Character Transmission Enable this option to transmit the check character along with Codabar bar code data. $CCBCT00(CR) Codabar Check Character Transmission = Don’t Send $CCBCT01(CR) DEFAULT Codabar Check Character Transmission = Send Codabar Start/Stop Character Transmission Enable this option to enable/disable transmission of Codabar start and stop characters $CCBSS00(CR) Codabar Start/Stop Character Transmission = Don’t...
  • Page 155: Codabar Start/Stop Character Set

    Symbologies Enter/Exit Programming Mode Codabar Start/Stop Character Set This option specifies the format of transmitted Codabar start/stop characters $CCBSC00(CR) Codabar Check Character Set = ABCD/TN*E $CCBSC01(CR) Codabar Check Character Set = ABCD/ABCD $CCBSC02(CR) Codabar Check Character Set = abcd/tn*e $CCBSC03(CR) DEFAULT Codabar Check Character Set = abcd/abcd Codabar Start/Stop Character Match...
  • Page 156: Codabar Quiet Zones

    Enter/Exit Programming Mode Symbologies Codabar Quiet Zones Specifies the number of quiet zones for Codabar labels. Quiet zones are blank areas at the ends of a bar code and are typically 10 times the width of the narrowest bar or space in the label. $CCBLO02(CR) Codabar Quiet Zones = Quiet Zones on two sides $CCBLO03(CR)
  • Page 157: Codabar Set Length 1

    Symbologies Enter/Exit Programming Mode Codabar Set Length 1 This feature specifies one of the bar code lengths for Codabar Length ControlCodabar Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode.
  • Page 158: Codabar Set Length 2

    Enter/Exit Programming Mode Symbologies Codabar Set Length 2 This feature specifies one of the bar code lengths for Codabar Length ControlCodabar Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode.
  • Page 159: Abc Codabar

    Symbologies Enter/Exit Programming Mode ABC CODABAR The following options apply to the ABC Codabar symbology. ABC Codabar Enable/Disable Enables/Disables ability of reader to decode ABC Codabar labels. $CCBAB00(CR) DEFAULT ABC Codabar = Disable $CCBAB01(CR) ABC Codabar = Enable ABC Codabar Concatenation Mode Specifies the concatenation mode between Static and Dynamic.
  • Page 160: Abc Codabar Dynamic Concatenation Timeout

    Enter/Exit Programming Mode Symbologies ABC Codabar Dynamic Concatenation Timeout Specifies the timeout in 10-millisecond ticks used by the ABC Codabar Dynamic Concatenation Mode. $CCBDT05(CR) ABC Codabar Dynamic Concatenation Timeout = 50 msec $CCBDT0A(CR) ABC Codabar Dynamic Concatenation Timeout = 100 msec $CCBDT14(CR) DEFAULT...
  • Page 161: Abc Codabar Force Concatenation

    Symbologies Enter/Exit Programming Mode ABC Codabar Force Concatenation Forces labels starting or ending with D to be concatenated. $CCBFC00(CR) DEFAULT ABC Codabar Force Concatenation = Disable $CCBFC01(CR) ABC Codabar Force Concatenation = Enable Product Reference Guide...
  • Page 162: Code 11

    Enter/Exit Programming Mode Symbologies CODE 11 The following options apply to the Code 11 symbology. Code 11 Enable/Disable When disabled, the reader will not read Code 11 bar codes. $CC1EN00(CR) DEFAULT Code 11 = Disable $CC1EN01(CR) Code 11 = Enable Code 11 Check Character Calculation This option enables/disables calculation and verification of optional Code 11 check character.
  • Page 163: Code 11 Check Character Transmission

    Symbologies Enter/Exit Programming Mode Code 11 Check Character Transmission This feature enables/disables transmission of an optional Code 11 check character. $CC1CT00(CR) Code 11 Check Character Transmission = Don’t Send $CC1CT01(CR) DEFAULT Code 11 Check Character Transmission = Send Code 11 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 11 symbology.
  • Page 164: Code 11 Set Length 1

    Enter/Exit Programming Mode Symbologies Code 11 Set Length 1 This feature specifies one of the bar code lengths for Code 11 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode.
  • Page 165: Code 11 Set Length 2

    Symbologies Enter/Exit Programming Mode Code 11 Set Length 2 This feature specifies one of the bar code lengths for Code 11 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode.
  • Page 166: Gs1 Databar™ Omnidirectional

    Enter/Exit Programming Mode Symbologies GS1 DATABAR™ OMNIDIRECTIONAL The following options apply to the GS1 DataBar™ Omnidirectional (formerly RSS-14) symbology. GS1 DataBar™ Omnidirectional Enable/Disable When disabled, the reader will not read GS1 DataBar™ Omnidirectional bar codes. $C4BEN00(CR) DEFAULT GS1 DataBar™ Omnidirectional = Disable $C4BEN01(CR) GS1 DataBar™...
  • Page 167: Gs1 Databar™ Omnidirectional 2D Component

    Symbologies Enter/Exit Programming Mode GS1 DataBar™ Omnidirectional 2D Component This feature enables/disables a requirement that a 2D label component be decoded when a base label for this symbology is decoded. $C4B2D00(CR) DEFAULT GS1 DataBar™ Omnidirectional 2D Component = Disable (2D component not required) $C4B2D01(CR) GS1 DataBar™...
  • Page 168: Gs1 Databar™ Expanded Gs1-128 Emulation

    Enter/Exit Programming Mode Symbologies GS1 DataBar™ Expanded GS1-128 Emulation When enabled, GS1 DataBar™ Expanded bar codes will be translated to the GS1-128 label data format. $CXBU800(CR) DEFAULT GS1 DataBar™ Expanded GS1-128 Emulation = Disable $CXBU801(CR) GS1 DataBar™ Expanded GS1-128 Emulation = Enable GS1 DataBar™...
  • Page 169: Gs1 Databar™ Expanded Length Control

    Symbologies Enter/Exit Programming Mode GS1 DataBar™ Expanded Length Control This feature specifies either variable length decoding or fixed length decoding for the GS1 DataBar™ Expanded symbology. Variable Length: For variable-length decoding, a minimum length may be set. Fixed Length: For fixed-length decoding, two different lengths may be set. $CXBLC00(CR) DEFAULT GS1 DataBar™...
  • Page 170: Gs1 Databar™ Expanded Set Length 1

    Enter/Exit Programming Mode Symbologies GS1 DataBar™ Expanded Set Length 1 This feature specifies one of the bar code lengths for GS1 DataBar™ Expanded Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode.
  • Page 171: Gs1 Databar™ Expanded Set Length 2

    Symbologies Enter/Exit Programming Mode GS1 DataBar™ Expanded Set Length 2 This feature specifies one of the bar code lengths for GS1 DataBar™ Expanded Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode.
  • Page 172: Gs1 Databar™ Limited

    Enter/Exit Programming Mode Symbologies GS1 DATABAR™ LIMITED The following options apply to the GS1 DataBar™ Limited (formerly RSS Limited) symbology. GS1 DataBar™ Limited Enable/Disable When disabled, the reader will not read GS1 DataBar™ Limited bar codes. $CLBEN00(CR) DEFAULT GS1 DataBar™ Limited = Disable $CLBEN01(CR) GS1 DataBar™...
  • Page 173: Gs1 Databar™ Limited 2D Component

    Symbologies Enter/Exit Programming Mode GS1 DataBar™ Limited 2D Component This feature enables/disables a requirement that a 2D label component be decoded when a base label of this symbology is decoded. $CLB2D00(CR) DEFAULT GS1 DataBar™ Limited 2D Component = Disable (2D component not required) $CLB2D01(CR) GS1 DataBar™...
  • Page 174: Code 93 Check Character Calculation

    Enter/Exit Programming Mode Symbologies Code 93 Check Character Calculation Enables/disables calculation and verification of an optional Code 93 check character. $CC9CC00(CR) Code 93 Check Character Calculation = Disable $CC9CC01(CR) Code 93 Check Character Calculation = Enable Check C $CC9CC02(CR) Code 93 Check Character Calculation = Enable Check K $CC9CC03(CR) DEFAULT Code 93 Check Character Calculation = Enable Check C...
  • Page 175: Code 93 Length Control

    Symbologies Enter/Exit Programming Mode Code 93 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 93 symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set. Fixed Length: For fixed length decoding, two different lengths may be set.
  • Page 176: Code 93 Set Length 1

    Enter/Exit Programming Mode Symbologies Code 93 Set Length 1 Specifies one of the bar code lengths for Code 93 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode.
  • Page 177: Code 93 Set Length 2

    Symbologies Enter/Exit Programming Mode Code 93 Set Length 2 This feature specifies one of the bar code lengths for Code 93 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode.
  • Page 178: Code 93 Quiet Zones

    Enter/Exit Programming Mode Symbologies Code 93 Quiet Zones Enables/disables quiet zones for Code 93. $CC9LO02(CR) Code 93 Quiet Zones = Quiet Zones on two sides $CC9LO03(CR) DEFAULT Code 93 Quiet Zones = Small Quiet Zones on two sides The following options apply to the MSI symbology. MSI Enable/Disable Enables/Disables ability of reader to decode MSI labels.
  • Page 179: Msi Check Character Calculation

    Symbologies Enter/Exit Programming Mode MSI Check Character Calculation Enables/Disables calculation and verification of an optional MSI check character. $CMSCC00(CR) MSI Check Character Calculation = Disable $CMSCC01(CR) DEFAULT MSI Check Character Calculation = Enable Mod10 $CMSCC02(CR) MSI Check Character Calculation = Enable Mod11/10 $CMSCC03(CR) MSI Check Character Calculation = Enable Mod10/10 MSI Check Character Transmission...
  • Page 180: Msi Length Control

    Enter/Exit Programming Mode Symbologies MSI Length Control This feature specifies either variable length decoding or fixed length decoding for the MSI symbology. For variable length decoding, a minimum and maximum length may be Variable Length: set. For fixed length decoding, two different lengths may be set. Fixed Length: $CMSLC00(CR) DEFAULT...
  • Page 181: Msi Set Length 1

    Symbologies Enter/Exit Programming Mode MSI Set Length 1 This feature specifies one of the bar code lengths for . Length 1 is the MSI Length Control minimum label length if in Mode, or the first fixed length if in Variable Length Fixed Mode.
  • Page 182: Msi Set Length 2

    Enter/Exit Programming Mode Symbologies MSI Set Length 2 This feature specifies one of the bar code lengths for . Length 2 is the MSI Length Control maximum label length if in Mode, or the second fixed length if in Variable Length Fixed Mode.
  • Page 183: Plessey

    Symbologies Enter/Exit Programming Mode PLESSEY The following options apply to the Plessey symbology. Plessey Enable/Disable Enables/Disables ability of reader to decode Plessey labels. $CPLEN00CR) DEFAULT Plessey = Disable $CPLEN01CR) Plessey = Enable Plessey Check Character Calculation Enables/Disables calculation and verification of an optional Plessey check character. $CPLCC00(CR) Plessey Check Character Calculation = Disable $CPLCC01(CR)
  • Page 184: Plessey Check Character Transmission

    Enter/Exit Programming Mode Symbologies Plessey Check Character Transmission Enables/disables transmission of an MSI check character. $CPLCT00(CR) Plessey Check Character Transmission = Disable $CPLCT01(CR) DEFAULT Plessey Check Character Transmission = Enable Plessey Length Control This feature specifies either variable length decoding or fixed length decoding for the Plessey symbology.
  • Page 185: Plessey Set Length 1

    Symbologies Enter/Exit Programming Mode Plessey Set Length 1 This feature specifies one of the bar code lengths for Plessey Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode.
  • Page 186: Plessey Set Length 2

    Enter/Exit Programming Mode Symbologies Plessey Set Length 2 This feature specifies one of the bar code lengths for Plessey Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode.
  • Page 187: 2D Symbologies

    2D SYMBOLOGIES 2D Global Features • 2D Maximum Decoding Time on page • 2D Normal/Inverse Symbol Control on page 187 • 2D Structured Append on page 187 2D Symbologies The reader supports the following 2D symbologies (bar code types). Symbology-dependent options for each symbology are included in this chapter.
  • Page 188: 2D Maximum Decoding Time

    Enter/Exit Programming Mode 2D Symbologies 2D Maximum Decoding Time This feature specifies the maximum amount of time the software will spend attempting to decode a 2D label. The selectable range is 10 milliseconds to 2.55 milliseconds. $CDETM0A(CR) 2D Maximum Decoding Time = 100 msec $CDETM32(CR) 2D Maximum Decoding Time = 200 msec $CDETM23(CR)
  • Page 189: 2D Structured Append

    2D Symbologies Enter/Exit Programming Mode 2D Structured Append Enables/disables ability of reader to append multiple 2D Codes labels in a structured format. The structured append property is globally applied to the following symbologies, if these are enabled: • Data Matrix •...
  • Page 190: Aztec Code

    Enter/Exit Programming Mode 2D Symbologies Aztec Code Aztec Code Enable / Disable Enables/disables the ability of the reader to decode Aztec Code labels. $CAZEN00(CR) Aztec Code = Disable $CAZEN01(CR) DEFAULT Aztec Code = Enable Aztec Code Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology.
  • Page 191: Aztec Code Set Length 1

    2D Symbologies Enter/Exit Programming Mode Aztec Code Set Length 1 Specifies one of the bar code lengths for Aztec Code Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Characters can be set from 0001 to 3,832 characters in increments of 0001 (pad with zeroes).
  • Page 192: Aztec Code Set Length 2

    Enter/Exit Programming Mode 2D Symbologies Aztec Code Set Length 2 This feature specifies one of the bar code lengths for Aztec Code Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode.
  • Page 193: China Sensible Code

    2D Symbologies Enter/Exit Programming Mode China Sensible Code China Sensible Code Enable / Disable Enables/disables the ability of the reader to decode China Sensible Code labels. $CCSEN00(CR) DEFAULT China Sensible Code = Disable $CCSEN01(CR) China Sensible Code = Enable China Sensible Code Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology.
  • Page 194: China Sensible Code Set Length 1

    Enter/Exit Programming Mode 2D Symbologies China Sensible Code Set Length 1 Specifies one of the bar code lengths for China Sensible Code Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode.
  • Page 195: China Sensible Code Set Length 2

    2D Symbologies Enter/Exit Programming Mode China Sensible Code Set Length 2 This feature specifies one of the bar code lengths for China Sensible Code Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode.
  • Page 196: Data Matrix

    Enter/Exit Programming Mode 2D Symbologies Data Matrix Data Matrix Enable / Disable Enables/disables ability of reader to decode Data Matrix labels. $CDMEN00(CR) Data Matrix = Disable $CDMEN01(CR) DEFAULT Data Matrix = Enable Data Matrix Square/Rectangular Style Specifies the options available when reading Data Matrix with different form factors. Choices are: •...
  • Page 197: Data Matrix Length Control

    2D Symbologies Enter/Exit Programming Mode Data Matrix Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set. Fixed Length: For fixed length decoding, two different lengths may be set. $CDMLC00(CR) DEFAULT Data Matrix Length Control = Variable Length...
  • Page 198: Data Matrix Set Length 2

    Enter/Exit Programming Mode 2D Symbologies Data Matrix Set Length 2 This feature specifies one of the bar code lengths for Data Matrix Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode.
  • Page 199: Maxicode

    2D Symbologies Enter/Exit Programming Mode Maxicode Maxicode Enable / Disable Enables/disables ability of reader to decode Maxicode labels. $CMXEN00(CR) DEFAULT Maxicode = Disable $CMXEN01(CR) Maxicode = Enable Maxicode Primary Message Transmission Enables/disables the transmission of only the Primary Message when the Secondary Message is not readable.
  • Page 200: Maxicode Length Control

    Enter/Exit Programming Mode 2D Symbologies Maxicode Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set. Fixed Length: For fixed length decoding, two different lengths may be set. $CMXLC00(CR) DEFAULT Maxicode Length Control = Variable Length...
  • Page 201: Maxicode Set Length 2

    2D Symbologies Enter/Exit Programming Mode Maxicode Set Length 2 This feature specifies one of the bar code lengths for Maxicode Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode.
  • Page 202: Pdf417

    Enter/Exit Programming Mode 2D Symbologies PDF417 PDF417 Enable / Disable Enables/disables the ability of the reader to decode PDF417 labels. $CP4EN00(CR) PDF417 = Disable $CP4EN01(CR) DEFAULT PDF417 = Enable PDF417 Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology.
  • Page 203: Pdf417 Set Length 1

    2D Symbologies Enter/Exit Programming Mode PDF417 Set Length 1 Specifies one of the bar code lengths for PDF417 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only.
  • Page 204: Pdf417 Set Length 2

    Enter/Exit Programming Mode 2D Symbologies PDF417 Set Length 2 This feature specifies one of the bar code lengths for PDF417 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode.
  • Page 205: Micro Pdf417

    2D Symbologies Enter/Exit Programming Mode Micro PDF417 Micro PDF417 Enable / Disable Enables/disables the ability of the reader to decode Micro PDF417 labels $CMIEN00(CR) DEFAULT Micro PDF417 = Disable $CMIEN01(CR) Micro PDF417 = Enable Micro PDF417 Code 128 GS1-128 Emulation Specifies which AIM ID to use for MicroPDF labels when doing Code 128 or GS1-128 emulation.
  • Page 206: Micro Pdf417 Length Control

    Enter/Exit Programming Mode 2D Symbologies Micro PDF417 Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set. Fixed Length: For fixed length decoding, two different lengths may be set. $CMILC00(CR) DEFAULT Micro PDF417 Length Control = Variable Length...
  • Page 207: Micro Pdf417 Set Length 2

    2D Symbologies Enter/Exit Programming Mode Micro PDF417 Set Length 2 This feature specifies one of the bar code lengths for Micro PDF417 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length includes the bar code’s data characters only.
  • Page 208: Qr Code

    Enter/Exit Programming Mode 2D Symbologies QR Code QR Code Enable / Disable Enables/disables the ability of the reader to decode QR Code labels $CQREN00(CR) QR Code = Disable $CQREN01(CR) DEFAULT QR Code = Enable QR Code Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology.
  • Page 209: Qr Code Set Length 1

    2D Symbologies Enter/Exit Programming Mode QR Code Set Length 1 Specifies one of the bar code lengths for QR Code Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Characters can be set from 0001 to 7,089 characters in increments of 0001 (pad with zeroes).
  • Page 210: Qr Code Set Length 2

    Enter/Exit Programming Mode 2D Symbologies QR Code Set Length 2 This feature specifies one of the bar code lengths for QR Code Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode.
  • Page 211: Micro Qr Code

    2D Symbologies Enter/Exit Programming Mode Micro QR Code Micro QR Code Enable/Disable Enables/disables the ability of the reader to decode Micro QR Code labels MQEN00 DEFAULT Micro QR Code = Disable MQEN01 Micro QR Code = Enable Micro QR Code Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology.
  • Page 212: Micro Qr Code Set Length 1

    Enter/Exit Programming Mode 2D Symbologies Micro QR Code Set Length 1 Specifies one of the bar code lengths for Micro QR Code Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode.
  • Page 213: Micro Qr Code Set Length 2

    2D Symbologies Enter/Exit Programming Mode Micro QR Code Set Length 2 This feature specifies one of the bar code lengths for Micro QR Code Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode.
  • Page 214: Ucc Composite

    Enter/Exit Programming Mode 2D Symbologies UCC Composite UCC Composite Enable / Disable Enables/disables the ability of the reader to decode the stacked part of a UCC Composite label. Global This feature is not effective when Global AIM IDs are enabled (see " AIM ID"...
  • Page 215: Ucc Optional Composite Timer

    2D Symbologies Enter/Exit Programming Mode UCC Optional Composite Timer Specifies the amount of time the system will wait for the stacked part of a UCC Composite label before transmitting the linear label without an add-on. $CCMOT00(CR) DEFAULT UCC Optional Composite Timer = Timer Disabled $CCMOT01(CR) UCC Optional Composite Timer = 100msec $CCMOT02(CR)
  • Page 216: Postal Code Selection

    Enter/Exit Programming Mode 2D Symbologies Postal Code Selection Enables/disables the ability of the scanner to decode labels of a specific postal symbology. • Disable All Postal Codes • Australia Post • Postnet • Japan Post • Planet • • Royal Mail •...
  • Page 217: Postnet Bb Control

    2D Symbologies Enter/Exit Programming Mode Postal Code Selection — cont. $CPOEN06(CR) Postal Code Selection = Enable Japan Post $CPOEN07(CR) Postal Code Selection = Enable IMB $CPOEN08(CR) Postal Code Selection = Enable Sweden Post $CPOEN09(CR) Postal Code Selection = Enable Portugal Post Postnet BB Control Controls the ability of the scanner to decode B and B' fields of Postnet labels.
  • Page 218 2D Symbologies NOTES Gryphon™ I GFS4400...
  • Page 219: Software Configuration Strings

    RS-232 communications. Upon exiting Service Mode, the programmed baud rate will be restored. 2. Using Datalogic Aladdin (available on the Datalogic website) or a Terminal Emulation Program, send the Restore Current Interface (Custom) Default string to the reader using the syntax described on the next page.
  • Page 220: Command Syntax

    Software Configuration Strings 5. Send all the necessary command strings according to your application's requirements. Command Syntax 1. Enter Service (Serial String Programming) Mode $S<CR> This command automatically sets the reader communication to 115200 baud rate. Before continuing, please set the baud rate of the Terminal Emulation Program to 115200.
  • Page 221 Example 1: 1. $S<CR> Enter Service Mode. 2. $CLFCA02<CR> Write command "Convert to Lower Case" to current configuration. 3. $Ar<CR> Apply and Save Configuration to FLASH (permanent memory) and Exit Service Mode. Each configuration parameter setting removes the condition previously active for that parameter.
  • Page 222: Serial Configuration Strings

    Software Configuration Strings SERIAL CONFIGURATION STRINGS ENTER/EXIT CONFIGURATION COMMANDS Description Command Enter Service Mode (configuration) fixed 115200 Baud rate Exit Service Mode (configuration) return to programmed Baud rate Apply Configuration to RAM (temporary memory) and Exit Service Mode Apply and Save Configuration to FLASH (permanent memory) and Exit Service Mode To configure the reader using configuration strings, it must be placed into Service Mode, which automatically sets the reader communica-...
  • Page 223 INTERFACE SELECTION COMMANDS Description Command Restore Current Interface (Custom) Default Configuration HA00 RS232-STD HA05 USB-COM HA47 RS232-Wincor-Nixdorf HA12 USB-KBD HA35 USB-KBD-ALT HA2B USB KBD-APPLE HA2C To read a particular parameter setting from the reader, send the read parameter command without any value. The reader will respond with its currently configured value.
  • Page 224 Software Configuration Strings RS-232/USB-COM PARAMETERS Description Parameter Value Intercharacter Delay No delay or from 10 to 990 ms R2IC Host command character which dis- Disable Character R2DC ables the reader Host command character which Enable Character R2EC enables the reader ACK/NAK Options Disable R2AE...
  • Page 225 USB-KBD / USB-KBD-ALT / USB-KBD-APPLE PARAMETERS Description Parameter Value Keyboard Country Mode KBCO *Belgium *Britain Croatia Czechoslovakia Denmark *France *Germany Hungary *Italy Japanese (106 key) Norway Poland Portugal Romania Slovakia *Spain *Sweden Switzerland Send Control Characters CTRL + KEY KBSC CTRL + SHIFT + KEY Special Function KEY USB Keyboard Speed...
  • Page 226 Software Configuration Strings READING PARAMETERS Description Parameter Value 20 to 2,550 milliseconds (2.55 seconds) in 10ms Double Read Timeout SNDR increments Illumination Mode Disabled SPIL Triggered Enabled Operating Modes On Line SNRM Serial On Line Automatic Automatic (Object Sense) Phase Off Event Trigger Stop SPTO Timeout...
  • Page 227 DATA FORMAT Description Parameter Value Data Transmission On Decode LFTX After Phase Off Code Verifier Mode Disabled LFCV Transmit Wrong String Transmit Wrong Code Match String Any string of characters (max 20) between 00-FE COVS Wrong Code String Any string of characters (max 20) between 00-FE WCVS Case Conversion Disable...
  • Page 228 GS1-128 U8ID ISBT 128 I8ID Interleaved 2 of 5 I2ID Standard 2 of 5 S2ID Industrial 2 of 5 U2ID Datalogic 2 of 5 D2ID IATA IAID Codabar CBID ABC Codabar ACID GS1 Databar 14 (Omnidirectional) 4BID GS1 Databar Expanded...
  • Page 229 Any string of characters (max 3) between 00-FE Custom Code Identifiers Code 93 C9ID MSID Plessey PLID = Hex value from representing the ASCII character DIGITAL OUTPUT Description Parameter Value OUTPUT Activation Event Disable OUA1 Good Read No Read Wrong Code Deactivation Event Disable OUD1...
  • Page 230 Software Configuration Strings LED AND BEEPER INDICATORS Description Parameter Value Power On Alert Disable BPPU Enable Indicate Good Read On Decode BPIN After Transmit Good Read Beep Disable BPVO Enable Good Read Beep Length Time length from 10 to 2550 ms BPLE Good Read Led Duration Time length from 0 to 25,500 ms...
  • Page 231 CODE SELECTION Description Parameter Value UPC-A ABEN UPC-A Disable Enable ABCT Check Character Tx Disable Enable AB3B Expand to EAN-13 Disable Enable ABNS Number System Tx Disable Enable ABMR Minimum Reads One Read Two Reads Three Reads Four Reads CPCL Coupon Control Allow all coupon barcodes to be decoded Enable only UPC-A coupon decoding...
  • Page 232 Software Configuration Strings CODE SELECTION Description Parameter Value Enable 3BIN ISSN Conversion Disable Enable 3BF1 Flag 1 Character Disable Enable 3BMR Minimum Reads One Read Two Reads Three Reads Four Reads CPCL Coupon Control Allow all coupon barcodes to be decoded Enable only UPC-A coupon decoding Enable only GS1 Databar coupon decoding EAN-8...
  • Page 233 CODE SELECTION Description Parameter Value EAN/UPC Global Settings GBEN GTIN Format Disable Enable UNDL Decoding Level Disable Level 1 Level 2 Level 3 Level 4 Level 5 UNCO Character Correlation Disable Enable INMR In-Store Minimum Reads One Read Two Reads Three Reads Four Reads Code 39...
  • Page 234 Software Configuration Strings CODE SELECTION Description Parameter Value C3CT Code 39 Check Tx Disable Enable C3SS Code 39 Start/Stop Tx Disable Enable Decoding Options C3MR Minimum Reads One Read Two Reads Three Reads Four Reads C3DL Decoding Level Disable Level 1 Level 2 Level 3 Level 4...
  • Page 235 I8CE ISBT 128 Concatenation Disable Enable I8CM Concatenation Mode Static Dynamic I8DT Dynamic Concat. Timeout From 50 to 2550 ms Chain 0 - Chain 15 Contact Datalogic = Hex value from representing the decimal number (x10 ms) Product Reference Guide...
  • Page 236 Software Configuration Strings CODE SELECTION Description Parameter Value Interleaved 2 of 5 (I 2 of 5) I2EN I 2 of 5 Disable Enable I2LC Code Length Control Variable Fixed Length 1 (or Min Length) from 2 to 50 characters I2L1 Set Length (only even numbers) Length 2 (or Max Length) from 0 or from 2 to 50 char-...
  • Page 237 CODE SELECTION Description Parameter Value Standard 2 of 5 S2EN Standard 2 of 5 Disable Enable S2LC Code Length Control Variable Fixed S2L1 Set Length Length 1 (or Min Length) from 1 to 50 characters S2L2 Length 2 (or Max Length) 0 or from 1 to 50 characters Check Options S2CC Check Calculation...
  • Page 238 Disable Enable IATA IAEN IATA Disable Enable IACT Check Tx Disable Enable Datalogic 2 of 5 D2EN Datalogic 2 of 5 Disable Enable D2LC Code Length Control Variable Fixed D2L1 Set Length Length 1 (or Min Length) from 1 to 50 characters...
  • Page 239 CODE SELECTION Description Parameter Value Level 4 Level 5 D2CO Character Correlation Disable Enable D2ST Stitching Disable Enable Codabar CBEN Codabar Disable Enable CBLC Code Length Control Variable Fixed CBL1 Set Length Length 1 (or Min Length) from 3 to 50 characters CBL2 Length 2 (or Max Length) 0 or from 3 to 50 characters ABC Codabar...
  • Page 240 Software Configuration Strings CODE SELECTION Description Parameter Value Three Reads Four Reads CBDL Decoding Level Disable Level 1 Level 2 Level 3 Level 4 Level 5 CBCO Character Correlation Disable Enable CBIR Interdigit Ratio Any ratio or 1 to 10 CBLO Quiet Zones Quiet Zone on One Side...
  • Page 241 CODE SELECTION Description Parameter Value XBL1 Set Length Length 1 (or Min Length) from 1 to 74 characters XBL2 Length 2 (or Max Length) 0 or from 1 to 74 characters Expanded Decoding Options XBMR Minimum Reads One Read Two Reads Three Reads Four Reads CPCL...
  • Page 242 Software Configuration Strings CODE SELECTION Description Parameter Value Two Reads Three Reads Four Reads C9DL Decoding Level Disable Level 1 Level 2 Level 3 Level 4 Level 5 C9CO Character Correlation Disable Enable C9LO Quiet Zones No Quiet Zones Quiet Zone on One Side Quiet Zones on Two Sides Auto Virtual Quiet Zones on Two Sides...
  • Page 243 CODE SELECTION Description Parameter Value MSDL Decoding Level Disable Level 1 Level 2 Level 3 Level 4 Level 5 MSST Stitching Disable Enable Plessey PLEN Plessey Disable Enable PLLC Code Length Control Variable Fixed PLL1 Set Length Length 1 (or Min Length) from 1 to 50 characters PLL2 Length 2 (or Max Length) 0 or from 1 to 50 characters Check Options...
  • Page 244 Software Configuration Strings NOTES Gryphon™ I GFS4400...
  • Page 245: References

    Chapter 5 References This section contains explanations and examples of selected bar code features. See Configuration for the actual bar code labels used to configure the reader. Using Bar Codes, starting on page 21 RS-232 Parameters....................... 244 RS-232 Only......................244 RS-232/USB COM Parameters.................
  • Page 246: Rs-232 Parameters

    References RS-232 Parameters RS-232 Parameters RS-232 Only Baud Rate Baud rate is the number of bits of data transmitted per second. Set the reader's baud rate to match the baud rate setting of the host device. With an improper baud rate setting, data may not reach the host correctly.
  • Page 247: Rs-232/Usb Com Parameters

    RS-232 Parameters References RS-232/USB COM Parameters Intercharacter Delay This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments.
  • Page 248 References RS-232 Parameters ACK NAK Options This enables/disables the ability of the reader to support the RS-232 ACK/NAK protocol. When configured, the reader and/or host sends an “ACK” when it receives data properly, and sends “NAK” when the data is in error. Options are: •...
  • Page 249 RS-232 Parameters References NAK Character This setting specifies an ASCII character or hex value to be used as the NAK character. ASCII characters or any hex value from 0 to 0xFF can be selected. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters.
  • Page 250 References RS-232 Parameters ACK NAK Timeout Value This option specifies the amount of time the reader waits for an ACK character from the host following label transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15 seconds) in 200ms increments. A selection of 0 disables the timeout. To set this value: 1.
  • Page 251 RS-232 Parameters References ACK NAK Retry Count This feature specifies the number of times the reader retries a label transmission due to a retry condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the count, and a selection of 255 specifies unlimited retries.
  • Page 252 References RS-232 Parameters Disable Character Specifies the value of the RS-232 host command used to disable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters.
  • Page 253 RS-232 Parameters References Enable Character Specifies the value of the RS-232 host command used to enable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters.
  • Page 254: Usb Intercode Delay

    References RS-232 Parameters USB Intercode Delay Specifies the delay between labels transmitted to the host for this interface. The selectable range for this feature is from 0 to 99 seconds. Follow these instructions to set this feature: 1. Determine the desired setting. 2.
  • Page 255: Symbologies

    Symbologies References Symbologies Set Length Length Control allows you to select either variable length decoding or fixed length decoding for the specified symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set. Fixed Length: For fixed length decoding, two different lengths may be set. Set Length 1 This feature specifies one of the bar code lengths for Length Control.
  • Page 256: Data Editing

    ID code will be transmitted before the scanned bar code data. 00 - 20 Characters (ASCII) Additional advanced editing is available. See the Advanced formatting fea- tures in the Datalogic Aladdin configuration software, or contact Technical Support (as described on page 10) for more information.
  • Page 257: Global Prefix/Suffix

    Data Editing References • A prefix or suffix may be applied only to a specified symbology (reference 1D Code ) or across all symbologies (set via the Global features in this Selection, starting on page 93 chapter). • You can add any character from the (from 00-FF) on the inside back cover of ASCII Chart this manual as a prefix, suffix or Label ID.
  • Page 258: Global Aim Id

    References Data Editing Global AIM ID This feature enables/disables addition of AIM IDs for all symbology types. AIM label identifiers (as opposed to custom characters you select yourself as with label identifiers) can be included with scanned bar code data. AIM label identifiers consist of three characters as follows: •...
  • Page 259: Label Id

    Data Editing References Label ID A Label ID is a customizable code of up to three ASCII characters (each can be one of hex 0x01- 0xFF), used to identify a bar code (symbology) type. It can be appended previous to or following the transmitted bar code data depending upon how this option is enabled.
  • Page 260 References Data Editing USA Label ID set EU Label ID set Symbology Default Default Default Default Character ASCII Character ASCII DATABAR 14 COMPOSITE 523400 523400 DATABAR EXPANDED 525800 740000 DATABAR EXPANDED COMPOSITE 525800 525800 DATABAR LIMITED 524C00 760000 DATABAR LIMITED COMPOSITE 524C00 524C00 DATA MATRIX...
  • Page 261 Data Editing References USA Label ID set EU Label ID set Symbology Default Default Default Default Character ASCII Character ASCII 400000 5A0000 PDF417 500000 720000 PLESSEY 610000 610000 POSTAL AUSTRALIAN 244B00 244B00 POSTAL IMB 245600 245600 POSTAL JAPANESE 245200 245200 POSTAL KIX 245500 245500...
  • Page 262 References Data Editing Label ID: Set Individually Per Symbology To configure a Label ID individually for a single symbology: 1. Go to and scan the ENTER/EXIT bar code. page 57 2. Select Label ID position as either BEFORE (Enable as Prefix) or AFTER (Enable as suf- fix) by scanning the appropriate bar code in the section .
  • Page 263 Data Editing References Table 34 . Label ID Examples STEP ACTION EXAMPLES Scan the ENTER/EXIT bar code (Scanner enters Programming Mode) Determine placement of the Label ID characters BEFORE or AFTER with regard to scanned Enable as Prefix Enable as Suffix Enable as Prefix Enable as Suffix data using...
  • Page 264: Character Conversion

    References Data Editing Character Conversion Character conversion is an eight byte configuration item. The eight bytes are 4 character pairs represented in hexadecimal ASCII values. The first character in the pair is the character that will be converted. The second character in the pair is the character to convert to. If the character to convert in a pair is FF, then no conversion is done.
  • Page 265: Scanner Data Formatting Control

    Data Editing References Scanner Data Formatting Control No Read String This feature allows the transmission of a programmable character or string when no code has been decoded (No read) during a reading phase (On Line Mode only). To set this feature: 1.
  • Page 266 References Data Editing No wild card characters are supported. To set this feature: 1. Determine the desired character string (max 32). 2. Reference the ASCII Chart on the inside back cover of this manual to find the hex value assigned to the desired character. 3.
  • Page 267: Digital Output

    Digital Output References Digital Output Output Activation: Digital Output can set to be Activated/Deactivated when specified events occur. Selects whether the line is Active Low or Active High. Line State: Activation Event: Selects the event the line is activated on. Selectable events: Disabled, Good Read, No Read, Right Code, Wrong Code.
  • Page 268: Reading Parameters

    References Reading Parameters Reading Parameters Double Read Timeout Double Read Timeout prevents a double read of the same label by setting the minimum time allowed between reads of labels of the same symbology and data. If the unit reads a label and sees the same label again within the specified timeout, the second read is ignored.
  • Page 269: Good Read Led Duration

    Reading Parameters References Good Read LED Duration This feature specifies the amount of time that the Good Read LED remains on following a good read. The good read LED on time can be set within a range of 10 milliseconds to 2,550 milliseconds (0.001 to 2.55 seconds) in 100ms increments.
  • Page 270: Scanning Features

    References Scanning Features Scanning Features Operating Mode The following Operating Modes (Reading Modes) are supported: On Line In On Line mode, the reading phase is defined as the time between the Phase ON and Phase OFF events. The Phase events can be generated by an external input (trigger) or by the Trigger button.
  • Page 271: Digital Output

    Scanning Features References Phase Off Event: Specifies whether the reading phase is closed on a timeout or phase off event. The following selections are available: • Trigger Stop: the reading phase ends when the serial stop character (or string) is received. Timeout is disabled.
  • Page 272: Scanning Active Time

    References Scanning Features Scanning Active Time This setting specifies the amount of time that the reader stays in scan ON state once the state is entered. It controls the Timeout within On Line & Serial On Line read modes Phase Off Event. The range for this setting is from 1 to 255 seconds in 1-second increments.
  • Page 273: Aiming Duration Time

    Scanning Features References Aiming Duration Time Specifies the frame of time the aiming pointer remains on after decoding a label, when in On Line or Serial On Line mode. The range for this setting is from 1 to 255 seconds in 1-second increments.
  • Page 274: Multiple Labels Ordering By Code Symbology

    References Scanning Features Multiple Labels Ordering by Code Symbology This feature Specifies the transmission ordering by symbology type, when Multiple Labels per Frame is enabled.Up to six symbologies can be selected. Zeroes must be added to pad the string to 12 characters if not using all six symbologies. The labels are ordered first as specified in the output mask.
  • Page 275 Scanning Features References Table 40 . Symbology Hex Values Value Symbology ID Value Symbology ID Don't care GTIN5 UPC-A GTIN8 UPC-E S2OF5 EAN8 PDF417 EAN13 CODE11 UPC2 IATA UPC5 MICRO_PDF C128_ADDON GS1 DataBar_LIM_ID EAN128 GS1 DataBar_LIM_COMP C128_PROGRAMMING_LABEL GS1 DataBar_Omnidirectional_COMP CODE128 GS1 DataBar_EXP_COMP FNC3_C128_LABEL GENERIC_DATA...
  • Page 276 References Scanning Features NOTES Gryphon™ I GFS4400...
  • Page 277: Technical Specifications

    Appendix A Technical Specifications Table contains Physical and Performance Characteristics, User Environment and Regulatory information. Table 41. Technical Specifications Item Description Physical Characteristics Color Grey Height 1.54" / 39mm Dimensions Length 2.24" / 57mm Width 2.28" / 58 mm USB version - Approximately 6.3 ounces/170 g Weight (with cable, without bracket) RS-232 version - Approximately 7.2 ounces/204 g...
  • Page 278 Technical Specifications Item Description Current & Power Consumption Input current at 5V in Automatic (Object Sense) Reading Mode Operating (typical) 180 mA Operating (max) 250 mA 65 mA (On Line & Serial On Line Modes) Idle/standby (typical) 115 mA (Automatic Object Sense Mode) No idle in Automatic Mode Performance Characteristics Nominal Frame Rate...
  • Page 279 1D Bar Codes Standard 2 of 5; Interleaved 2 of 5 CIP (HR); Industrial 2 of 5; Discrete 2 of 5; Datalogic 2 of 5 (China Post Code/Chinese 2 of 5); IATA 2of5 Air cargo code; Code 11; Codabar; Codabar (NW7);...
  • Page 280 Technical Specifications NOTE: The Scanner can also decode mirrored images of 2D matrix codes Datamatrix, QR Code and Maxicode. GFS4450-9 version: RS-232 Standard Interfaces Supported GFS4470 version:USB-COM, USB-Keyboard, USB-OEM User Environment Operating Temperature -4° to 122° F (-20° to 50° C) Storage Temperature -4°...
  • Page 281 Technical Specifications Figure 7. Output Connection Output Connection Vext 14Vdc max GFS4450-9 USER INTERFACE 5 GND Figure 8. Using GFS4450-9 Power Input Trigger Using GFS4450-9 Power GFS4450-9 EXT TRIGGER TRIGGER 5 GND Figure 9. Using External Power Supply Input Trigger Using External Power GFS4450-9 EXT TRIGGER...
  • Page 282: Imager Labeling

    Technical Specifications Imager Labeling The sample labels shown below are for illustrative purposes only. Please view the labels on your product for actual details, as they may vary. Scanner Labels Aiming System ™ The Gryphon aiming system meets the Class 2 requirements for laser safety. The laser infor- mation is located on the window of the Scanner and is shown below.
  • Page 283: Led And Beeper Indications

    Technical Specifications LED and Beeper Indications Button and LED Status The top of the product has a button and three indicator LEDs: ON = Power ON POWER OFF = Power OFF or standby (only USB (yellow LED) version) ON = Good Read GOOD Blinks = USB enumeration or interface (green LED)
  • Page 284 Technical Specifications Indicator Description Beeper Reader 'chirps' six Indicates that a host Limited Scanning times at the highest connection is not Label Read frequency and current established. volume. Reader Active The reader is active The LED is lit steadily Mode and ready to scan.
  • Page 285: Error Codes

    Technical Specifications Programming Mode The following indications ONLY occur when the reader is in Programming Mode Indicator Description Beeper LED blinks continu- Label Programming A valid programming label Reader sounds four Mode Entry has been scanned. low frequency beeps. ously Reader sounds three Label Programming times at lowest fre-...
  • Page 286 Technical Specifications NOTES Gryphon™ I GFS4400...
  • Page 287: Aimer Calibration

    Appendix B Aimer Calibration The Scan Modules in the GFS4400 series contain laser-based aiming system consisting of four corner dots and a center crosshair pattern that helps define the reading volume. The center cross location in the imager's Field Of View (FOV) is recorded and logged in the system's non- volatile memory (calibration process), and facilitates the Central Code Only operation.
  • Page 288 Examples shown use the terminal window tool provided within Datalogic Aladdin configuration utility (available from the Datalogic website), or any other serial terminal utility. In Aladdin with terminal window opened, check the Log box and then click on Select Connection to provide the reader’s COM port information.
  • Page 289 Auto Calibration To Auto Calibrate the scanner, do the following: 1. Position and steady the reader in front of a plain flat sheet of paper or surface at a Depth of Field (distance) that is most appropriate for the application. 2.
  • Page 290 Aimer Calibration NOTES Gryphon™ I GFS4400...
  • Page 291: Standard Defaults

    Appendix C Standard Defaults The most common configuration settings are listed in the “Default” column of the table below. Page references are also provided for feature descriptions and programming bar codes for each parameter. A column has also been provided for recording of your preferred default settings for these same configurable features.
  • Page 292 Standard Defaults Page Parameter Default Your Setting Number Enable Character ‘E’ USB KEYBOARD Country Mode U.S. Keyboard Send Control Characters Intercode Delay 100 ms Intercode Delay No Delay Caps Lock State Caps Lock OFF USB Keyboard Speed 1 ms USB Keyboard Numeric Keypad Standard Keys USB-OEM USB-OEM Device Usage...
  • Page 293 Standard Defaults Page Parameter Default Your Setting Number DIGITAL OUTPUT Activation Event Disable Deactivation Event Disable Deactivation Timeout 005 = 500 msec Activation State Closed READING PARAMETERS Double Read Timeout 1 Second Power On Alert Power-up Beep Good Read: When to Indicate After Decode Good Read Beep Type Mono...
  • Page 294 Standard Defaults Page Parameter Default Your Setting Number Aiming Off Aiming Duration Timer After Decoding Green Spot Duration 300 ms Mobile Phone Mode Enable Mobile Bias No Mobile Bias Partial Label Reading Control Enable Mirror Reading Mode Disable Decode Negative Image Disable Multiple Label Reading Multiple Labels per Frame...
  • Page 295 Standard Defaults Page Parameter Default Your Setting Number GTIN Formatting Disable EAN 13 (Jan 13) EAN 13 Enable/Disable Enable EAN 13 Check Character Transmission Send EAN-13 Flag 1 Character Transmit EAN-13 ISBN Conversion Disable 2D Component Not EAN-13 2D Component Required ISSN ISSN Enable/Disable...
  • Page 296 Standard Defaults Page Parameter Default Your Setting Number Code 39 Set Length 1 Code 39 Set Length 2 Trioptic Code Trioptic Code Enable/Disable Disable Code 32 (Italian Pharmaceutical Code) Code 32 Enable/Disable Disable Code 32 Check Char Transmission Don’t Send Code 32 Start/Stop Character Transmission Don’t Transmit Code 39 CIP (French Pharmaceutical Code)
  • Page 297 Standard Defaults Page Parameter Default Your Setting Number ISBT 128 Force Concatenation Disable ISBT 128 Concatenation Mode Static ISBT 128 Dynamic Concatenation Timeout 200 msec Interleaved 2 of 5 I 2 of 5 Enable/Disable Disable I 2 of 5 Check Character Calculation Disable I 2 of 5 Check Character Transmission Send...
  • Page 298 Standard Defaults Page Parameter Default Your Setting Number IATA Check Character Transmission Enable Codabar Codabar Enable/Disable Disable Codabar Check Character Calculation Don’t Calculate Codabar Check Character Transmission Send Codabar Start/Stop Character Transmission Transmit Codabar Start/Stop Character Set abcd/abcd Codabar Start/Stop Character Match Don’t Require Match Small Quiet Zones on Codabar Quiet Zones...
  • Page 299 Standard Defaults Page Parameter Default Your Setting Number GS1 DataBar™ Expanded GS1 DataBar™ Expanded Enable/Disable Disable GS1 DataBar™ Expanded GS1-128 Emulation Disable 2D component not GS1 DataBar™ Expanded 2D Component required GS1 DataBar™ Expanded Length Control Variable GS1 DataBar™ Expanded Set Length 1 GS1 DataBar™...
  • Page 300 Standard Defaults Page Parameter Default Your Setting Number Enable Plessey std. check Plessey Check Character Calculation char. verification Plessey Check Character Transmission Enable Plessey Length Control Variable Plessey Set Length 1 Plessey Set Length 2 CODE SELECTION - 2D SYMBOLOGIES 2D Maximum Decoding Time 350msec 2D Structured Append...
  • Page 301: Qr Code Set Length 1

    Standard Defaults Page Parameter Default Your Setting Number PDF417 Set Length 1 PDF417 Set Length 2 2,710 Micro PDF417 Enable / Disable Disable Micro PDF AIM ID and Micro PDF417 Code 128 GS1-128 Emulation label type Micro PDF417 Length Control Variable Micro PDF417 Set Length 1 Micro PDF417 Set Length 2...
  • Page 302 Standard Defaults NOTES Gryphon™ I GFS4400...
  • Page 303: Sample Bar Codes

    Appendix D Sample Bar Codes The sample bar codes in this appendix are typical representations for their symbology types. 1D Bar Codes UPC-A EAN-13 Code 39 Code 128 Interleaved 2 of 5 Product Reference Guide...
  • Page 304 Sample Bar Codes 1D Bar Codes — continued Code 32 Codabar Code 93 Code 11 Gryphon™ I GFS4400...
  • Page 305: Gs1 Databar

    Sample Bar Codes GS1 DataBar™ GS1 DataBar™ Omnidi- GS1 DataBar™ variants must be enabled to read the bar codes below (see rectional on page 164 GS1 DataBar™ 14 GS1 DataBar™ Expanded GS1 DataBar™ Limited GS1 DataBar™ Truncated GS1 DataBar™ Stacked (01)12345678901231 GS1 DataBar™...
  • Page 306: D Bar Codes

    Sample Bar Codes 2D Bar Codes Aztec Datamatrix ABCabc ABCabc China Sensible Code MaxiCode ABCabc PDF 417 Micro PDF 417 12345678 ABCabc QR Code Micro QR Code ABCDEF ABCabc Composite Codes DataBar™ Expanded Stacked Composite GS1-128 Composite Gryphon™ I GFS4400...
  • Page 307: Keypad

    Appendix E Keypad Use the bar codes in this appendix to enter numbers as you would select digits/characters from a keypad. Product Reference Guide...
  • Page 308 Gryphon™ I GFS4400...
  • Page 309: Reserved Characters

    Appendix F Reserved Characters Reserved Characters Hex Value Notes [SOH] 0x01 [BEL] 0x07 0x23 0x24 0x30 0x33 0X42 0X44 0X45 0X46 0X52 0X53 0x68 0x69 0x73 0x74 [FF] 0xFF Reserved Strings C can be used without [CR] or inside a C<up to 36 chars>[CR] 0x43 <xxx>...
  • Page 310 NOTES Gryphon™ I GFS4400...
  • Page 311: Scancode Tables

    Appendix G Scancode Tables Control Character Emulation Control character emulation selects from different scancode tables as listed in this appendix. Each of the control character sets below are detailed by interface type in the tables. These apply to USB Keyboard platforms. Control Character 00 : Characters from 00 to 0x1F are sent as control character Ctrl+Keys, special keys are located from 0x80 to 0xA1.
  • Page 312: Interface Type Pc At Ps/2, Usb-Keyboard Or Usb-Keyboard For Apple

    Interface Type PC AT PS/2, USB-Keyboard or USB-Keyboard for APPLE Table 43. Scancode Set When Control Character is 00 or 01 NULL C(S)+A C(S)+B C(S)+C C(S)+D C(S)+E C(S)+F C(S)+G C(S)+J C(S)+K C(S)+L Enter C(S)+N C(S)+O C(S)+P C(S)+Q C(S)+R C(S)+S C(S)+T C(S)+U C(S)+V C(S)+W...
  • Page 313 Interface Type PC AT PS/2, USB-Keyboard or USB-Keyboard for APPLE — cont. Table 44. Scancode Set When Control Character is 02 Enter Ar↓ Ar↑ Al↓ Al ↑ Cl ↓ Cl ↑ Cr ↓ Cr ↑ S+ Tab Enter Pg Up ...
  • Page 314: Interface Type Pc At Ps/2 Alt Mode Or Usb-Keyboard Alt Mode

    Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode Table 45. Scancode Set When Control Character is 00 or 01 Alt+000 Alt+001 Alt+002 Alt+003 Alt+004 Alt+005 Alt+006 Alt+007 Alt+010 Alt+011 Alt+012 Alt+014 Alt+015 Enter Alt+016 Alt+017 Alt+018 Alt+019 Alt+020 Alt+021 Alt+022...
  • Page 315 Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode — cont. Table 46. Scancode Set When Control Character is 02 Enter Ar↓ Ar↑ Al↓ Al ↑ Cl ↓ Cl ↑ Cr ↓ Cr ↑ S+ Tab Enter Pg Up ...
  • Page 316: Digital Interface

    Digital Interface Table 47. Scancode Set When Control Character is 00 or 01 NULL C(S)+A C(S)+B C(S)+C C(S)+E C(S)+F C(S)+G C(S)+J C(S)+K C(S)+L Enter C(S)+N C(S)+O C(S)+P C(S)+Q C(S)+R C(S)+S C(S)+T C(S)+U C(S)+V C(S)+W C(S)+X C(S)+Y C(S)+Z C(S)+\ C(S)+^ C(S)+_ Space “...
  • Page 317: Ibm31Xx 102-Key

    IBM31xx 102-key Table 49. Scancode Set When Control Character is 00 or 01 NULL C(S)+A C(S)+B C(S)+C C(S)+E C(S)+F C(S)+G C(S)+J C(S)+K C(S)+L Enter C(S)+N C(S)+O C(S)+P C(S)+Q C(S)+R C(S)+S C(S)+T C(S)+U C(S)+V C(S)+W C(S)+X C(S)+Y C(S)+Z C(S)+\ C(S)+^ C(S)+_ Space “...
  • Page 318: Ibm Xt

    IBM XT Table 51. Scancode Set When Control Character is 00 or 01 NULL C(S)+A C(S)+B C(S)+C C(S)+E C(S)+F C(S)+G C(S)+H C(S)+J C(S)+K C(S)+L Enter C(S)+N C(S)+O C(S)+P C(S)+Q C(S)+R C(S)+S C(S)+T C(S)+U C(S)+V C(S)+W C(S)+X C(S)+Y C(S)+Z C(S)+\ C(S)+^ C(S)+_ Space “...
  • Page 319: Microsoft Windows Codepage 1252

    Microsoft Windows Codepage 1252 Windows-1252 is a character encoding of the Latin alphabet, used by default in the legacy components of Microsoft Windows in English and some other Western languages. Product Reference Guide...
  • Page 320 NOTES Gryphon™ I GFS4400...
  • Page 321 NOTES Product Reference Guide...
  • Page 322 NOTES Gryphon™ I GFS4400...
  • Page 323: Ascii Chart

    ASCII Chart ASCII ASCII ASCII ASCII Hex No. Hex No. Hex No. Char. Char. Char. Char. ‘ “ & ’ < >...
  • Page 324 Obere Hauptstraße 42A D-84072 Au i. d. Hallertau Tel: +49 8752 86917-0 kontakt@unglaube.de www.unglaube.de www.datalogic.com Datalogic ADC, Inc. 959 Terry Street Eugene, OR 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 © 2012 Datalogic Scanning, Inc. 820049614 (Rev A) August 2012...

This manual is also suitable for:

Gryphon i gfs4450-9Gryphon i gfs4470

Table of Contents